Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+10

Reference Dimensions - No Tolerance & Secondary Reporting Options

Kyle Brummans 7 лет назад в Metrology Software / PC-DMIS обновлен AKASH 3 года назад 2 1 дубликат

Two main attributes:

The ability to toggle tolerances off.  (Basic and Reference dimensions)  

The ability to have a second set of dimensional reporting options or several reporting profiles (Dimension Color Settings)

This helps with quality control.  Right now, we either 'open' tolerance or don't report.  There are instances where it is desirable to have values of basics and references with-out it hindering production mentality/reactions.  Often I also output XYZ coordinates for In-Car and zero tolerance them, as the T-value is what's important/desired.

+10
Завершен

Browse Button in the “New Measurement Routine” Dialog

Thomas Schopp 8 лет назад в Metrology Software / PC-DMIS обновлен neil kay 6 лет назад 3

It would be nice to have a browse Button in the “New Measurement Routine” Dialog to create a new Routine in a Subfolder from the “Default Measurement Routine Directory”.

A lot of customers have a Folder Structure depend on their Customers, for Example:

Measurement Routines

  • Volkswagen
  • Audi
  • BMW

Etc. Actual it’s not possible to create a new Routine in the right Folder directly. Each new Routine exists as file corpse in the “Default Measurement Routine Directory” after Save as in a Subfolder.

+10

Sample Hits/Feature for Adaptive Scanning

David Courtney 9 лет назад в Metrology Software / PC-DMIS обновлен damonh 2 года назад 6

Please add sample hits/feauture options to the adaptive scanning auto circle properties.


Image 92

+10
Завершен

Bring back an old function that when viewing a report in the report window you could be taken back to that dimension in the program for editing.

Tim H 9 лет назад в Metrology Software / PC-DMIS обновлен prasanna 3 года назад 9

this function was in older versions. quite handy when proving a program or when dimensions get updated. Way faster than the find function.

+9
Завершен

Excel form report file name

Liviu 7 лет назад в Metrology Software / PC-DMIS обновлен neil kay 6 лет назад 3

As a Pc-Dmis User i wish to be able to use various trace field's from the measuring routine in the naming of the excel form report name.

Image 267

Image 269

+9
Завершен

NEW GD&T preview in edit window . Make preview for new GD&T in edit window like it was for Legacy Dimensions.

tomeq 8 лет назад в Metrology Software / PC-DMIS обновлен Neil Ryan 3 года назад 17

Image 209

+9

report should print as text pdf (not image) so it can be copied and pasted to other applications

Kevin Watters 9 лет назад в Metrology Software / PC-DMIS обновлен neil kay 6 лет назад 4

When you print a report as a pdf it should be rendered as text, not an image so that you can copy and past from it to other applications.

+8

Availability Laser Sensor NIKON LC15Dx for PC-DMIS required

andreas vogt@mtu de 3 года назад в Metrology Software / PC-DMIS 0

Up to now laser sensor NIKON LC15Dx is not available in PC-DMIS.

This sensor is used on LEITZ CMM with PC-DMIS as Clientsoftware via Technollogy Server.

+8

Migrate PC-DMIS configurations and settings when installing a new version.

Eric Liard 4 года назад в Metrology Software / PC-DMIS обновлен robert radley 3 года назад 1

Have the option on install to migrate configs from the previous version. 

+8

disallow invalid feature names

Aaron Baldauf 6 лет назад в Metrology Software / PC-DMIS обновлен mihael rakic 4 года назад 1

I would like, that PC-DMIS makes it impossible to use “invalid” characters (spaces or special characters) in feature names or at least warn the user when using them.

I have seen many problems come from it first hand and also countless forum threads about it.



Сервис поддержки клиентов работает на платформе UserEcho