Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+6
تم الإنجاز

Easy way to populate results in excel based first article travelers

David Pinedo منذ 6 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 7

Looking for a way to populate results in specific custom order in Excell based first article travelers.

+6
تم الإنجاز

Create Straight Tube Project

trung van منذ 7 سنة في Metrology Software / TubeShaper تم التحديث من قبل anthony vianna منذ 3 سنة 4

Crazy as it sounds, but we do have straight tubes that we measure too, some with flanges or fittings at the ends.  I know that there is the toolbox to measure a straight, but it is limited to just a straight.  Would like to be able to create and inspect a straight tube with or without flange profiles and check for the deviations.

+6
قيد المراجعة

Allow tolerance warning threshold to be configured

neil kay منذ 7 سنة في Metrology Software / Inspect محدّث منذ 4 سنة 2

UK customer has requested a way in Inspect to specify a % of tolerance, and if dimensions are within tolerance, but above the % of tolerance, they would be marked in yellow on the dimension summary screen at the end of execution.

+6
تم الإنجاز

Modification of the Protocol Header / Customer Request

Holger منذ 7 سنة في Metrology Software / TubeShaper تم التحديث من قبل anthony vianna منذ 3 سنة 5

We need more Variables ind the Header of the Protokoll.

The Customers need to insert.

1. Customer

2. Part

3. Controller

4. Tube Material

5. Bender

6. Comments

7. ...etc.

+6
تم الإنجاز

See CAD model inside Inspect Interface.

cdsuttles منذ 8 سنة في Metrology Software / Inspect تم التحديث من قبل neil kay منذ 5 سنة 11

Would like to be able to view the CAD model within the Inspect user interface while the program is executing. Similar to the current Operator mode functionality.

+6

Remembering past measurements

Mitja Smrekar منذ 8 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 4

Now PC-DMIS remembers only measurements made on the last part. A lot of time I need a complete data of part that was measured in past. It could be set to remember last xx measured parts. I know that Calypso has this feature.

+6
تم الإنجاز

DRF feature construction option(s) - relative to other features/datums

Jon Wood (NinjaBadger) منذ 8 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 19 1 مكرر

Add options to construct Datum features in such a way that they reflect the standard.


Example - Datum A is a Plane, and Datum B is a cylinder bore nominally perpendicular to the plane.


As per both ISO and ASME standards, Datum B would be a Max Insc Cylinder Perpendicular to Dat A.


It's easy enough to construct a Max Insc cylinder, but this wouldn't be forced perpendicular to the plane, currently you'd have to measure it as a series of circles, then construct a Max Insc Circle in the correct workplane after levelling to Dat A.


See bottom image for example (image shows shaft not bore but principle is the same).


Image 7


Like wise construct a datum plane from a measured plane relative to another feature (Top image)

+6

Make it possible to re-enumerate feature numbers after program is written/edited.

hellcatrydr منذ 8 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Your program is finished but some points or features were added and their out of numerical order.

A Re-number feature would put them all in ascending order.

+5

Ability to Assign a Dimension as Attribute

JIM منذ 2 سنة في Metrology Software / PC-DMIS 0

I would like the ability to create an attribute dimension, similar to a "Keyed In" dimension that has a non-numerical value of either "PASS" OR "FAIL" and the ability to pass that result to reports or Excel exports.  Currently, all defined dimensions are numerical.

+5

Complete autocalibration routine

Hunter منذ 2 سنة في Metrology Software / PC-DMIS 0

Autocalibration Currently does not remeasure failed tips. My suggestion is to implement a feature within the Autocalibration routine that allows it to remeasure the tips that failed the standard deviation. As well as adding a feature within the autocalibration code that allows you to select the calibration sphere when the qualtool has been moved only. This would be used for all autocalibration within that code as well but only selected at the beginning of the program to ensure correct vector and size are used. My expectation if this gets implemented is when i leave on Friday, i can start the autocalibration routine and come back on Monday with no tips that have been outside of the standard deviations.



خدمة دعم العملاء من خلال UserEcho