Hexagon Measurement SystemsNo matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.
Thanks for your assistance in helping us shape the future. |
|
Auto circle
Add auto circle for star probe
Datum definition allow multiple characters
Allow to add multiple characters on a datum definition not only 2.

New point construction method: "high point"
Finding the "high point" of a feature or scan is a very common measurement task.
In pc-dmis, this is a complex task, that requires an understanding of array indexing, and significant manual entry into a generic feature. It is prone to error, is very time consuming, and for users never exposed to a programming language it's a complete non-starter.
A simple, interface-based point construction method could be added to address these issues. The new method should be based on the DMIS method "CONST/EXTREM". It is very complete, and since pc-dmis imports DMIS code - it only makes sense to have a 1 to1 mapping of the DMIS definition.
Angular Length Reporting
Maybe there is an easy way to report it ;if we have either a check box on the location (angle between) dialog window like "from formula" or an easier assignment set will be great.
Here is the code in order to report it :

CIR1 =FEAT/CIRCLE,CARTESIAN,OUT,LEAST_SQR
THEO/<98.516,-145.613,-2.547>,<0,0,1>,506.5,0
ACTL/<98.516,-145.613,-2.547>,<0,0,1>,506.5,0
MEAS/CIRCLE,4,ZPLUS
HIT/BASIC,NORMAL,<51.696,103.272,-2.55>,<-0.1848771,0.9827616,0>,<51.696,103.272,-2.55>,USE THEO=YES HIT/BASIC,NORMAL,<99.287,107.636,-1.309>,<0.0030416,0.9999954,0>,<99.287,107.636,-1.309>,USE THEO=YES
HIT/BASIC,NORMAL,<166.819,98.253,-3.669>,<0.2697032,0.9629435,0>,<166.819,98.253,-3.669>,USE THEO=YES
HIT/BASIC,NORMAL,<227.698,72.212,-2.661>,<0.5100969,0.8601169,0>,<227.698,72.212,-2.661>,USE THEO=YES
ENDMEAS/
LIN1 =FEAT/LINE,CARTESIAN,UNBOUNDED
THEO/<31.03,97.103,-1.56>,<-0.7071068,-0.7071068,0>
ACTL/<31.03,97.103,-1.56>,<-0.7071068,-0.7071068,0>
MEAS/LINE,2,ZPLUS
HIT/BASIC,NORMAL,<31.03,97.103,1.086>,<-0.7071068,0.7071068,0>,<31.03,97.103,1.086>,USE THEO=YES
HIT/BASIC,NORMAL,<-13.352,52.72,-4.207>,<-0.7071068,0.7071068,0>,<-13.352,52.72,-4.207>,USE THEO=YES
ENDMEAS/
LIN2 =FEAT/LINE,CARTESIAN,UNBOUNDED
THEO/<239,62.251,-5.264>,<0,-1,0>
ACTL/<239,62.251,-5.264>,<0,-1,0>
MEAS/LINE,2,ZPLUS
HIT/BASIC,NORMAL,<239,62.251,-5.016>,<1,0,0>,<239,62.251,-5.016>,USE THEO=YES
HIT/BASIC,NORMAL,<239,53.115,-5.512>,<1,0,0>,<239,53.115,-5.512>,USE THEO=YES
ENDMEAS/
PNT1 =FEAT/POINT,CARTESIAN,NO
THEO/<239,65.1,-5.264>,<0,-1,0>
ACTL/<239,65.1,-5.264>,<0,-1,0>
CONSTR/POINT,PIERCE,CIR1,LIN2
PNT2 =FEAT/POINT,CARTESIAN,NO
THEO/<32.922,98.995,-1.56>,<-0.7071068,-0.7071068,0>
ACTL/<32.922,98.995,-1.56>,<-0.7071068,-0.7071068,0>
CONSTR/POINT,PIERCE,CIR1,LIN1
LIN3 =FEAT/LINE,CARTESIAN,UNBOUNDED,NO
THEO/<98.516,-145.613,-2.547>,<-0.259008,0.9658673,0.0038973>
ACTL/<98.516,-145.613,-2.547>,<-0.259008,0.9658673,0.0038973>
CONSTR/LINE,BF,3D,CIR1,PNT2,,
OUTLIER_REMOVAL/OFF,3
FILTER/OFF,WAVELENGTH=0
LIN4 =FEAT/LINE,CARTESIAN,UNBOUNDED,NO
THEO/<98.516,-145.613,-2.547>,<0.5546916,0.8319869,-0.0107257>
ACTL/<98.516,-145.613,-2.547>,<0.5546916,0.8319869,-0.0107257>
CONSTR/LINE,BF,3D,CIR1,PNT1,,
OUTLIER_REMOVAL/OFF,3
FILTER/OFF,WAVELENGTH=0
DIM ANGL1= 2D ANGLE FROM LINE LIN4 TO LINE LIN3 ,$
GRAPH=OFF TEXT=OFF MULT=10.00 OUTPUT=BOTH
AX MEAS NOMINAL +TOL -TOL DEV OUTTOL
A 48.703 48.703 0.010 0.010 0.000 0.000 ----#----
ASSIGN/V1=((2*3.14*CIR1.R.MEAS)/360)*ANGL1.A.MEAS
F1 =GENERIC/NONE,DEPENDENT,CARTESIAN,OUT,$
NOM/XYZ,<0,0,0>,$ MEAS/XYZ,<0,0,0>,$
NOM/IJK,<0,0,1>,$
MEAS/IJK,<0,0,1>,$
RADIUS/0,0,$
ANGLE/215.5,V1,$
DISTANCE/0,0
DIM LOC1= LOCATION OF PLANE F1 UNITS=MM ,$
GRAPH=OFF TEXT=OFF MULT=10.00 OUTPUT=BOTH HALF ANGLE=NO
AX MEAS NOMINAL +TOL -TOL DEV OUTTOL
A 215.160 215.500 0.500 0.500 -0.340 0.000 -#-------
END OF DIMENSION LOC1
Allow Max & Min Index of Polar Radius from a scanned feature
When finding a high point of a linear feature it's possible to use the Maxindex assignment relative to a specific axis. For example "maxindex(scan.x)". This will return the max value in X for that scan.
When scanning radial features and finding a max Polar Radius, one would expect to use "maxindex(scan.PR)" to return the max value for PR in that scan. Thus giving a high point of a radius for example.
This command doesn't work with polar radius.
PC-DMIS – Explicit ClearanceCube ON/OFF Commands in the Measurement Program
Feature Enhancement Request: Explicit ClearanceCube ON/OFF Commands in PC-DMIS
As a professional CMM metrologist and PC-DMIS programmer at Vite Automotive, I would like to propose an improvement to the current implementation of ClearanceCube.
Current issue
One of the main limitations of ClearanceCube is the lack of clearly visible and explicit ON/OFF commands directly within the PC-DMIS measurement program.
Currently, ClearanceCube behavior is controlled through settings that are not sufficiently transparent in the Edit Window.
This becomes particularly problematic when a measurement program is transferred to another programmer or CMM operator.
For example, a measurement program may contain no explicit MOVE/POINT commands, while the CMM still performs automatic clearance movements controlled by ClearanceCube.
For someone unfamiliar with the original program configuration, it can be very difficult to understand how and why the machine moves between measurement features.
From a professional programming perspective, this is unnecessarily confusing and inconvenient. It also makes troubleshooting, program maintenance, and verification of safe machine movements more difficult.
Proposed improvement
I would like to suggest implementing explicit ClearanceCube control commands directly into the PC-DMIS measurement program.
These commands should allow programmers to:
- Enable ClearanceCube at any specific point in the measurement sequence.
- Disable ClearanceCube wherever necessary.
- Clearly identify whether ClearanceCube is currently ON or OFF directly in the Edit Window.
- Change ClearanceCube behavior locally within the program without relying exclusively on global settings.
- Make the intended movement strategy understandable to other programmers and operators without requiring additional explanations.
Ideally, these commands should be clearly visible, editable, and documented, with an unambiguous indication of the active ClearanceCube status.
Expected benefits
- Improved transparency and readability of measurement programs.
- Easier troubleshooting and maintenance.
- Better control and understanding of automatic CMM movements.
- Reduced risk of unexpected machine movements.
- Improved usability when transferring programs between programmers, operators, or different CMM machines.
A measurement program should be as self-explanatory as possible, especially when it controls the physical movements of a coordinate measuring machine.
I believe this enhancement would provide significant practical benefits for professional PC-DMIS programmers and CMM users.
I would appreciate it if this proposal could be reviewed by the PC-DMIS Product Management and Software Development teams.
Thank you for your consideration.
Thread Pitch Selection
It would be helpful to add a dropdown menu for thread pitch selection instead of requiring users to manually type in the pitch for each thread. The dropdown could include common inch and metric thread sizes, along with an option for LH threads, allowing users to quickly select the correct pitch from a list. This would save time and make the thread creation process more consistent and user-friendly
Ability to choose report method from Cartesian to radial or spherical on geometrical results.
We have many drawings that have surface profiles, the dimensions may apply to flat, angles, curved, radial and spherical surfaces which have BASIC controls that when reported, do not match the drawing at all, this is due to the fact that when choosing to report a surface profile, the data shown is in Cartesian and no choice for radial or spherical to report. When programming to create a new coordinate that sets the origin to a location and be able to measure radial points or surfaces, the output data needs to have the relationship to match the drawing call out, this helps with making decision on mold making, machining and or part configuration. Customers also have no correlation of results to drawing, X,Y,Z does not corollate if features are radial or spherical when looking at the surface profile point data to evaluate.
AUTO PLANE RINGS
I would like to see an option where we can adjust the distance between multiple rings when checking a radial auto plane. We of course have the option to adjust the size of the rings but, to my knowledge, don't have the option to adjust the distance between.
Comment Box Update!
I think the Comment box could use some help. I've been using PCDMIS since the 2014 version and its basically untouched in 10 years. As an offline programmer, the comments are sometimes the only way I can communicate to the inspection operators.
I have seen some people on here asking for Font Types and Colors, and i think that's a really great idea!
I would also like to see more ALT codes translated correctly to the comment box, or maybe add more than the four symbols at the bottom of the Comment Text Box. GD&T uses so many different symbols to communicate there should be a library to choose from when typing out or operator comments.
Even as I type this out, I'm looking at the options i have to edit my text and I would love to see something similar to this woven into the comment section of PCDMIS. (see below)

Service d'assistance aux clients par UserEcho