Somehow mark Significant Characteristics (SC's) (CC's) on a report.

Jayson Woodard vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 0
I would like to somehow make all the Significant Charateristics  stand out of the report without moving them out of balloon order. For example.. F1, F2, F3(SC), F4, F6(CC)....
0
Fertiggestellt

Default setting of the calculation type of the elements

Wolle vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von Matt vor 4 Jahren 6

Currently, an elemente open always with the setting of the last use. 

But since most of the time is the default setting ASME or ISO 1101, it would be an advantage if this be can adjusted in advance. 

I would suggest here to insert an pullup meneu in the menu „NEW“ where the default setting of the elements can be preset.


0

Vision Auto Features - Percentage based enhancement

Kyle Brummans vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 0

Currently, when editing settings for vision auto features each segment is given it's own setting, clicking back and forth between options or un-segmenting and editing then re-segmenting is your only option.  It would be nice to check all features for editing or just certain features for editing.

0

Vision Auto Circle - Start/End position enhancment

Kyle Brummans vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 0

Currently, if i'm running percentage based vision circles, I have to guess and check between settings to align gears to teeth while maintaining all of the appropriate settings.

Allow the start and end positions to increment simultaneously by a degree while maintaining settings.

0

Vision Circles - Percentage improvement

Kyle Brummans vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 0

Currently vision segments are restricted to manual segmenting or a generic 10% percent based increment.

Problem - Gear circles often have in excess of 20 teeth and percentages do not line up with arc length of given teeth.

Solution allow percentages in increments of 1%

0

Variable focus - Vision / Focus Plane

Kyle Brummans vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 1

It would be nice to support a quick focus where I can set an intial amount of pre-focus at a lower mag then fine-tune the focus in high-mag - in one feature.  Similar to re-measure of a circle.

It would also be nice to have a quick focus feature incorporated into an auto plane where either the first point, three points, or all points have that ability.  Rather than multiple alignments, several times.

0

Change Point Density in the edit window instead of having to change it in the Probe Otions ( F10 ) area

Vondy vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 0
0

iso or asme Tangent point tolerance

michele pastore vor 5 Jahren in Metrology Software / TubeShaper aktualisiert von neil kay vor 5 Jahren 0

Exist the table? 

thanks

0
Fertiggestellt

Add a key in the quick Measurement Strategy Widget where you can difine samble hits .

Spring vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 1

Add a key in the quick Measurement Strategy Widget where you can difine samble hits ,for now it can't change the sample hits in PC-DMIS R2 with just 0 spacer. Or allow the programer change the hits position manually with the intuitive path line displayed.

0
Abgelehnt

collision detection causing probe head to drop in z causing crashes into calibration sphere when at a >90° probe angle

Travis vor 5 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 5 Jahren 1