0

Probe Utilities - Add Search, Sort and hide unmark tips for Active Tip List

davehocum 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

Probe Utilities

Add a Search box to search for a specific tip.

Add a Sort to have the ability to ascend or descend tips.

Add the ability to Hide unmark tips after selecting Mark Used.


0

Move Program Mode Icon to Measured Features Toolbar

Kingsld1 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

As far as I know Program Mode is only used with Measured Features.  Makes sense to me to take it off the graphic modes toolbar and move it to where it is used.   Easier to find and semi-logical.  

0

Optical flatness measurement

Wolle 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 10

We often have to measure very small optical flatnesses on contact surfaces. 

Here it would be useful if I had to Focus with once window only. 

Simply define the measurement window and the division of the measuring range analogous to the measuring method from Werth GmbH.


0

Add polar/catersian toggle to measured features

benjamin frickmann 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 2


Offer the same simple way to swap measured features between polar and cartesian coordinates, as is possible in auto features.

0

Min-Max Radius

Kyle Brummans 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

Canned  dimensional support for:

-Measuring a fixed radius then measuring an average point back to it's center point.

-Measuring a fixed radius then reporting out the high and the low points back to center and giving a max and min radius.

0

Scanning with the ability to lasso CAD points when picking Boundary points

Scott Wingard 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

The ability to lasso CAD points when picking your Boundary points when creating your scan

0

Probe prioritizing in loops

Salisbury83 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

When I create a part loop for 100 parts I would like the ability to run probe 1 on all 100 parts before switching to probe 2 and starting at part 1 again with the correct alignment.  If i create both probes in same loop program it takes more time changing probes than it does checking each part. The loop does create the alignments like this ABC[1] right now but once out of the loop and switching to probe 2 their is no way to recall alignment ABC[1] and start from part 1 thru 100 again. This would eliminate having to create external alignments using variables.

0

Backup with Protect

Don Narr 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

Add a backup folder to the Set Search Path list.  When program is protected also back it up to the backup folder.

0

Target Dimension Modifier (Support for Assignments).

Kyle Brummans 5 years ago in Metrology Software / PC-DMIS updated by neil kay 4 years ago 0

The ability to modify targets without effecting alignment changes. 