Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+3

Reporting the width of an o-ring groove ( or the difference between an I.D. and an O.D. )

PcDmis 3 года назад в Metrology Software / PC-DMIS обновлен Guillermo 3 года назад 4
+3

True position tolerance add on - In Use Legacy Dimension

srinivasan 3 года назад в Metrology Software / PC-DMIS обновлен 3 года назад 0

Image 465


Dear Team,


During the position tolerance callout, we don't have the separate column for position tolerance update . Instead of that every time we modifying in report callout.

In addition to +/- tolerance, if you provide the position tolerance column it would be very useful.

If any other method available in current state, please let me know.

Regards
Srinivasan N

+3

Vectors of deviation in CAD protocol

Dominik Braun 4 года назад в Metrology Software / PC-DMIS 0

Hello,

we need to have the option to show the vectors of the deviation in our protocol.

It is possible in the graphical window in PC-DMIS, so why isnt it possible in the "CADONLY" protocol e.g.?

Here is a screenshot what I mean:

Image 450

Thanks in advance

+3

summary view, color scheme, similar to edit window colors

damonh 4 года назад в Metrology Software / PC-DMIS обновлен davehocum 4 года назад 1

add a color scheme to the summary view, similar to the edit window color scheme that can be saved and recalled.

+3

Datum feature in edit feature window

Garrett W 4 года назад в Metrology Software / PC-DMIS обновлен Trevor McLaughlin 4 года назад 1

Add a feature in the screen for editing a feature (plane, cylinder, etc) to assign it as a datum instead of going through dimension datum screen and/or gd&t dimension. 

+3

Enable "To Points" toggle in all auto-features

DAN_M_413 4 года назад в Metrology Software / PC-DMIS 0

Regarding the "To Points" toggle in the auto-feature dialogue box..


Would it be possible to make this toggle work for every type of auto-feature?

Right now, you can only use "To Points" on autocircle, autoplane, and autocylinder. The toggle is "grayed out" for lines, cones, spheres, etc. Adding this functionality would be a good enhancement IMO. 

Thanks for your time,

-Dan

+3

Move probe to center of calibration sphere before next rotation

Big John 4 года назад в Metrology Software / PC-DMIS 0

In the calibration cycle, the possibility that the probe moves to the center of the calibration sphere before the next rotation move. This is useful if using a small CMM. It saves room and the eliminates the chance of a collision with the CMM support legs. 

+3

Scale behavior with 4k resolution on monitors should be reworked

Thilo Graf 5 лет назад в Metrology Software / PC-DMIS обновлен 3 года назад 2

We have new workstations with 4k monitors but the behavior of PCDMIS was disappointing while switching to the desired resolution with suitable scaling for our monitors.

We are using PCDMIS 2019 R2, with NVIDIA Quadro P4000

Here some screenshots for demonstration

Current Windows settings with 1920x1080 / 100%.

Image 399

So it looks now with loss of edge sharpness, which has particularly bad effects on the graphics window.

This is our solution at the moment, but the screen is slightly blurry.
We had imagined differently, especially working with CAD models.

Image 388

If we set the better resolution and the appropriate scaling for our monitors, it looks like this:

Now switch to 

Image 390

now it looks so after PCDMIS restart on the same monitor

Image 395

Image 398

Font and icons seems to be ok but the report window is not really usable without up scaling.

With up scaled settings e.g. 200% in the report window it looks not really nice, moreover the labels inside status

window are not scalable. You need a magnifying glass for this. ;-)


Please fix this behavior. Thanks

+3

I would like to calculate the area focus and the area of scans

Hans Brunner GmbH 5 лет назад в Metrology Software / PC-DMIS обновлен neil kay 5 лет назад 2

We have irregular contours (turtle, Easter eggs, seahorses) and need the area and their from closed scans.

Our competitors are already working with this for a long time.

Сервис поддержки клиентов работает на платформе UserEcho