Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+5
Fertiggestellt

New point construction method: "high point"

dave amstutz (djams) vor 9 Jahren in Metrology Software / PC-DMIS aktualisiert von Neil Ryan vor 2 Jahren 2

Finding the "high point" of a feature or scan is a very common measurement task.


In pc-dmis, this is a complex task, that requires an understanding of array indexing, and significant manual entry into a generic feature. It is prone to error, is very time consuming, and for users never exposed to a programming language it's a complete non-starter.


A simple, interface-based point construction method could be added to address these issues. The new method should be based on the DMIS method "CONST/EXTREM". It is very complete, and since pc-dmis imports DMIS code - it only makes sense to have a 1 to1 mapping of the DMIS definition.

+5

Add a length and width spacer option for auto planes

bman vor 9 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 1

Currently PC-DMIS has a square spacer that can be set for auto planes. It would be nice if we could specify the length and width of the spacer

+5

Basic Dimension option

gsciola vor 9 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 0

How about a Basic Dimension option, in the Location Tool Box. That way the basic dimensions don't need to have tolerances.

+5

Angular Length Reporting

SalihaGungor vor 9 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 1

Image 12Maybe there is an easy way to report it ;if we have either a check box on the location (angle between) dialog window like "from formula" or an easier assignment set will be great.

Here is the code in order to report it :


Image 14

CIR1 =FEAT/CIRCLE,CARTESIAN,OUT,LEAST_SQR
THEO/<98.516,-145.613,-2.547>,<0,0,1>,506.5,0
ACTL/<98.516,-145.613,-2.547>,<0,0,1>,506.5,0
MEAS/CIRCLE,4,ZPLUS
HIT/BASIC,NORMAL,<51.696,103.272,-2.55>,<-0.1848771,0.9827616,0>,<51.696,103.272,-2.55>,USE THEO=YES HIT/BASIC,NORMAL,<99.287,107.636,-1.309>,<0.0030416,0.9999954,0>,<99.287,107.636,-1.309>,USE THEO=YES
HIT/BASIC,NORMAL,<166.819,98.253,-3.669>,<0.2697032,0.9629435,0>,<166.819,98.253,-3.669>,USE THEO=YES
HIT/BASIC,NORMAL,<227.698,72.212,-2.661>,<0.5100969,0.8601169,0>,<227.698,72.212,-2.661>,USE THEO=YES
ENDMEAS/
LIN1 =FEAT/LINE,CARTESIAN,UNBOUNDED
THEO/<31.03,97.103,-1.56>,<-0.7071068,-0.7071068,0>
ACTL/<31.03,97.103,-1.56>,<-0.7071068,-0.7071068,0>
MEAS/LINE,2,ZPLUS
HIT/BASIC,NORMAL,<31.03,97.103,1.086>,<-0.7071068,0.7071068,0>,<31.03,97.103,1.086>,USE THEO=YES
HIT/BASIC,NORMAL,<-13.352,52.72,-4.207>,<-0.7071068,0.7071068,0>,<-13.352,52.72,-4.207>,USE THEO=YES
ENDMEAS/
LIN2 =FEAT/LINE,CARTESIAN,UNBOUNDED
THEO/<239,62.251,-5.264>,<0,-1,0>
ACTL/<239,62.251,-5.264>,<0,-1,0>
MEAS/LINE,2,ZPLUS
HIT/BASIC,NORMAL,<239,62.251,-5.016>,<1,0,0>,<239,62.251,-5.016>,USE THEO=YES
HIT/BASIC,NORMAL,<239,53.115,-5.512>,<1,0,0>,<239,53.115,-5.512>,USE THEO=YES
ENDMEAS/
PNT1 =FEAT/POINT,CARTESIAN,NO
THEO/<239,65.1,-5.264>,<0,-1,0>
ACTL/<239,65.1,-5.264>,<0,-1,0>
CONSTR/POINT,PIERCE,CIR1,LIN2
PNT2 =FEAT/POINT,CARTESIAN,NO
THEO/<32.922,98.995,-1.56>,<-0.7071068,-0.7071068,0>
ACTL/<32.922,98.995,-1.56>,<-0.7071068,-0.7071068,0>
CONSTR/POINT,PIERCE,CIR1,LIN1
LIN3 =FEAT/LINE,CARTESIAN,UNBOUNDED,NO
THEO/<98.516,-145.613,-2.547>,<-0.259008,0.9658673,0.0038973>
ACTL/<98.516,-145.613,-2.547>,<-0.259008,0.9658673,0.0038973>
CONSTR/LINE,BF,3D,CIR1,PNT2,,
OUTLIER_REMOVAL/OFF,3
FILTER/OFF,WAVELENGTH=0
LIN4 =FEAT/LINE,CARTESIAN,UNBOUNDED,NO
THEO/<98.516,-145.613,-2.547>,<0.5546916,0.8319869,-0.0107257>
ACTL/<98.516,-145.613,-2.547>,<0.5546916,0.8319869,-0.0107257>
CONSTR/LINE,BF,3D,CIR1,PNT1,,
OUTLIER_REMOVAL/OFF,3
FILTER/OFF,WAVELENGTH=0
DIM ANGL1= 2D ANGLE FROM LINE LIN4 TO LINE LIN3 ,$
GRAPH=OFF TEXT=OFF MULT=10.00 OUTPUT=BOTH
AX MEAS NOMINAL +TOL -TOL DEV OUTTOL
A 48.703 48.703 0.010 0.010 0.000 0.000 ----#----
ASSIGN/V1=((2*3.14*CIR1.R.MEAS)/360)*ANGL1.A.MEAS
F1 =GENERIC/NONE,DEPENDENT,CARTESIAN,OUT,$
NOM/XYZ,<0,0,0>,$ MEAS/XYZ,<0,0,0>,$
NOM/IJK,<0,0,1>,$
MEAS/IJK,<0,0,1>,$
RADIUS/0,0,$
ANGLE/215.5,V1,$
DISTANCE/0,0
DIM LOC1= LOCATION OF PLANE F1 UNITS=MM ,$
GRAPH=OFF TEXT=OFF MULT=10.00 OUTPUT=BOTH HALF ANGLE=NO
AX MEAS NOMINAL +TOL -TOL DEV OUTTOL
A 215.160 215.500 0.500 0.500 -0.340 0.000 -#-------
END OF DIMENSION LOC1

+5
Fertiggestellt

Allow Max & Min Index of Polar Radius from a scanned feature

Ben Fisher vor 9 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 3 Jahren 3

When finding a high point of a linear feature it's possible to use the Maxindex assignment relative to a specific axis. For example "maxindex(scan.x)". This will return the max value in X for that scan.


When scanning radial features and finding a max Polar Radius, one would expect to use "maxindex(scan.PR)" to return the max value for PR in that scan. Thus giving a high point of a radius for example.


This command doesn't work with polar radius.

+4

Save the PC-DMIS version/SP/Schema so that we can identify what version of PC-DMIS is needed to open this file.

Matt Beecher vor 11 Monaten in Metrology Software / PC-DMIS aktualisiert von Neil Challinor vor 5 Monaten 2

Can we get some way to record what version/schema of PC-DMIS is required to open a particular PC-DMIS file?  With the rolling cutoff and some users having a mix of schema for their routines, I fear difficulties with using the migration utilities in the future. 

+4

Add UPR as smart parameter in the measurement strategy editor

Stan Deenen vor 1 vor einem Jahr in Metrology Software / PC-DMIS 0

As more and more customers are asking us to scan (with a probe) all features, they also got their standards for using the filters in scanning. In those standards, they also ask for a specific UPR which relates to the current diameter. For example, Ø8 and smaller require a UPR setting of 15. Ø8-Ø25 require UPR 50 etc.

I'd like to add this as a smart parameter in the Measurement Strategy Editor to make sure we also use the correct settings.

+4

AUTO PLANE RINGS

barnett_james vor 2 Jahren in Metrology Software / PC-DMIS aktualisiert von Neil Challinor vor 5 Monaten 3

I would like to see an option where we can adjust the distance between multiple rings when checking a radial auto plane. We of course have the option to adjust the size of the rings but, to my knowledge, don't have the option to adjust the distance between.

+4

Comment Box Update!

DavidthatDay vor 2 Jahren in Metrology Software / PC-DMIS 0

I think the Comment box could use some help.  I've been using PCDMIS since the 2014 version and its basically untouched in 10 years.  As an offline programmer, the comments are sometimes the only way I can communicate to the inspection operators.  

I have seen some people on here asking for Font Types and Colors, and i think that's a really great idea!

I would also like to see more ALT codes translated correctly to the comment box,   or maybe add more than the four symbols at the bottom of the Comment Text Box.  GD&T uses so many different symbols to communicate there should be a library to choose from when typing out or operator comments. 

Even as I type this out, I'm looking at the options i have to edit my text and I would love to see something similar to this woven into the comment section of PCDMIS. (see below)

Image 599


+4

Possibility to disable automatic highlighting of the feature on which the cursor is located

R. Kempe vor 2 Jahren in Metrology Software / PC-DMIS aktualisiert von Robin Wick vor 2 Jahren 2

There should be an option to disable automatic highlighting of a feature on which the cursor is placed.

When programming, the large shadow of the highlight can interfere. Especially with single circles this is a disadvantage.

At the moment there is only the possibility to change the color of the highlight.