Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

Motorized probe magazine

Bill Kulpa il y a 5 ans dans Hardware / Coordinate Measuring Machines mis à jour par ALBERT706 il y a 4 ans 4

Develop a motorized probe magazine much like every machining center has.

That way it could be mounted in the dead space at the end of the Y axis of most machines.

When a probe change is needed PC-DMIS would move the machine to a predetermined point for that port, the port would extend to the Z rail and unload or load a new probe. This would allow better use of the measuring envelop and enable use of that dead space at the end of the machine.


0

Allow measured feature coordinates to convert to auto features

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 3

Often there are tools in auto features that are quite useful.  Often enough I spend time manually converting the coordinates of a measured feature into an autofeature to get the benefits it prescribes.

0

Add Angle for sample hit rotation (circle)

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 0

We can control the angles of the hits for the circle, it would be nice to independently control the angle of the sample hits

0
Écarté

The new Updater should list all versions of Pc-Dmis That you have installed on the computer

Michael A Wildschutz Sr il y a 5 ans dans Metrology Software / Universal Updater mis à jour par neil kay il y a 4 ans 1

The all new Updater should be able to list all versions of Pc-Dmis that is installed on that particular computer not just the newest version

0

More Vision Algorithms

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 10

I've seen competing software that has no problem with edges I have problems with in PC°DMIS.


Whenever I'm on a vision project, I always struggle to get edge parameters correct until lots of trial.


Nearest Nominal and Matching Edge are sometimes very amazing and work quite well, but often there are program parameters and changes that are not feasible with those tools (at least not with out lots of work, meaning if I quote for the struggle I lose the work anyway).


Can we develop a plan for implementing better algorithms?  I can, and possibly the rest of the community, can submit difficult tasks to measure and submit them for review.

0

Program Icon changes with Version

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 4

Change the ICON of a program in the explorer window depending on the version it is saved in.

Example:

-2018 R1 & 2 Icon would be the number 18

-2017 R1 & 2 icon would be the number 17


etc..

We have multiple customers that require different versions of PCDMIS - before we send the program we have to verify that it is in the correct format.  This would be a quick visual to verify that it has been saved correctly.

0

Conditional Group Controls

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 0

PC°Dmis has a group command.

It would be nice if it were possible to check conditions inside of the group command and then the group command would output a conditional variable.

Example:

I place all of my critical feature dimensions inside of a group command.  I then set the conditional statement for:

-any out of tolerance condition inside group = to 1

-any % of tolerance condition inside group = to -1

This condition is written to an external record (comma separated)

I can now program an external system to fetch these results and use it to control process signals i.e. stop production/quality alert (Andon Signaling) etc. 

0

Bug Watch Forum

Kyle Brummans il y a 5 ans dans Metrology Software mis à jour par neil kay il y a 4 ans 1

Unfortunately, metrology software in general is riff with bugs.  - It happens -


Often, we are stuck to find them on our own with only our own attempts of validation before calling the help line.

It would be very nice and awesome if the following could happen.

-Allow users to sign a confidentiality agreement (not to expose flaws exorbitantly)

-Allow those users access to the list of known/confirmed bugs

-Open a forum to the discussion and troubleshooting of bugs and workarounds to help save time and potentially inaccuracies.

0

probe files

Bill Kulpa il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 0

I'd like the ability to change the contents of a probe file without having to reconstruct the entire probe build. We have 15 production machines and are trying to simplify the process of changing a broken stylus. An under trained person won't know that a 4 x 67mm custom stylus is ITP part number STHM504011069.

If I could just edit the stylus names in the existing probe files in a text file format it would be much easier than having to create all new probe files.

Image 262



0

tesselation of probe

Gábor Tóth il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 2

Hi,

Many user change the open GL tesselation value to 1 -> 0,1.

It would be great some possibilities that the Probe ball and shaft tesselation also can to improve...

Thanks in advance!