Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+6

PROBE CALIBRATION

Sergio 7 år siden i Metrology Software / PC-DMIS opdateret af neil kay 6 år siden 9


Add a key in the calibration area where you can save and import a list of angles because every time you create a probe you have to start from zero.

+6
Under vurdering

Jog Box

John Demaray 8 år siden i Metrology Hardware / Coordinate Measuring Machines opdateret af sarchibald 12 måneder siden 4

CMMs need the option to have wireless jog boxes. I trip over the cord all the time and wheel over it with my chair.

+6
Færdig

Easy way to populate results in excel based first article travelers

David Pinedo 8 år siden i Metrology Software / PC-DMIS opdateret af neil kay 6 år siden 7

Looking for a way to populate results in specific custom order in Excell based first article travelers.

+6

Allow tolerance warning threshold to be configured

neil kay 8 år siden i Metrology Software / Inspect opdateret af Neil KAY (Hexagon) 1 måned siden 3

UK customer has requested a way in Inspect to specify a % of tolerance, and if dimensions are within tolerance, but above the % of tolerance, they would be marked in yellow on the dimension summary screen at the end of execution.

+6
Færdig

See CAD model inside Inspect Interface.

cdsuttles 9 år siden i Metrology Software / Inspect opdateret af neil kay 6 år siden 11

Would like to be able to view the CAD model within the Inspect user interface while the program is executing. Similar to the current Operator mode functionality.

+6
Færdig

Remembering past measurements

Mitja Smrekar 10 år siden i Metrology Software / PC-DMIS opdateret af Neil Challinor 1 måned siden 5

Now PC-DMIS remembers only measurements made on the last part. A lot of time I need a complete data of part that was measured in past. It could be set to remember last xx measured parts. I know that Calypso has this feature.

Svar
Neil Challinor 1 måned siden

Please take a look at the Package Measurement Routine functionality in PC-DMIS 2026.1.

+6
Færdig

DRF feature construction option(s) - relative to other features/datums

Jon Wood (NinjaBadger) 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 6 år siden 19 1 dublet

Add options to construct Datum features in such a way that they reflect the standard.


Example - Datum A is a Plane, and Datum B is a cylinder bore nominally perpendicular to the plane.


As per both ISO and ASME standards, Datum B would be a Max Insc Cylinder Perpendicular to Dat A.


It's easy enough to construct a Max Insc cylinder, but this wouldn't be forced perpendicular to the plane, currently you'd have to measure it as a series of circles, then construct a Max Insc Circle in the correct workplane after levelling to Dat A.


See bottom image for example (image shows shaft not bore but principle is the same).


Image 7


Like wise construct a datum plane from a measured plane relative to another feature (Top image)

+6

Make it possible to re-enumerate feature numbers after program is written/edited.

hellcatrydr 10 år siden i Metrology Software / PC-DMIS opdateret af Neil Challinor 10 måneder siden 1

Your program is finished but some points or features were added and their out of numerical order.

A Re-number feature would put them all in ascending order.

+5

Save the PC-DMIS version/SP/Schema so that we can identify what version of PC-DMIS is needed to open this file.

Matt Beecher 1 år siden i Metrology Software / PC-DMIS opdateret af Neil Challinor 10 måneder siden 2

Can we get some way to record what version/schema of PC-DMIS is required to open a particular PC-DMIS file?  With the rolling cutoff and some users having a mix of schema for their routines, I fear difficulties with using the migration utilities in the future. 

+5

Have the clearance cube wrap around the form of the part instead of a cube that has deadspace in it

Richmond 2 år siden i Metrology Software / PC-DMIS opdateret af damonh 4 uger siden 2

This would save lots of time for some parts. Think of it like the shield from the Dune movies. The clearcube should form around the part