Add (M) to the concentricity/coaxiality FCF builder

Jörgen Andersson (vpt se) 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 9

ISO allows for the (M) modifier on concentricity and coaxiality, but I have yet to see this added to PC-DMIS. In order for my conc/coax evaluations to comply with the drawing, I must either do a bonus calculation, then an conc/coax evaluation with the calculated tolerance - or, use position to evaluate the conc/coax where the (M) modifier can be used.

+1

Password protected mode

Selahattin Akkaya 8 years ago in Metrology Software / Inspect updated by neil kay 5 years ago 1

I should be able to set passwords for certain sections for operator mode. I want to choose the sections to be password protected.

+1

Report Window

gbeebout 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 1

Please look into adding the ability to move/view the report window on a second monitor.

+1
Completed

Can we make the Ser Number field "Text Only".

gsciola 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 5

Currently a Serial Number like 123-456 will be read as -333. I understand that I can add an underscore, but doesn't it just make sense to allow the serial number to be entered as it appears on the part?

+1

Tools for cleaning up the Recent Files, and viewing the complete path

anders isaksson 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 1

It would be nice to be able to easily remove files from the Recent Files list, for example by right clicking and getting a menu [Remove This, Remove Non-existing, Remove All].


It would also be good to be able to see the full path of a recent file, for example as a tool tip when hovering with the mouse.


(none of the existing Categories match - maybe add User Interface to the Categories?)

+1
Completed

user group and run programs

romeo matkovic 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 2

Pcdmsi should have login inside aplication. For login diferents privilegies to create, chenge run programs. Need tohave user friendly and configurable desktop for runing programs, like separate desk. One desk for programing another for run programs . Like some of older Part program runs with picture and programs descriptions.

+1

Measurement plan editor

romeo matkovic 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Generaly, editor for multiply feature at the same time. for parameteres like probes, stily, speed, move, prehit, ...

+1

Ability to detect the extreme outer surface for Nominal Point Creation

Bryan 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Ability to detect the extreme outer surface along surface vector for Nominal Point Creation when assy has multiple overlay surfaces in order to build nominals for section slices as found in Blade Nominal File creattion.

+1

White Light Scanning - Calibration - Calibration Offset

Anthony Fotion 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Currently PC-DMIS does not have a way for a CWLS system to calibrate the offset within the probe utilities edit window. You can construct the probe but for calibration it requires a completely separate process. This would be for a Vision primary system with TTP & CWLS probe capabilities.

Currently I have 3 different CWLS lenses and 3 different Vision lenses.

In order to calibrate the offset between each possible configuration of lenses requires me to program a separate calibration routine for each configuration and then uses manually coded scripting to update the PRB.BAS file.

This would be a great thing to add.