Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+1

Lower matrix

Bill Kulpa 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Add a field in the lower level matrix calibration dialog box which informs the technician when the last time the lower matrix cal was performed.

+1

Bookmark location markers on scrollbar

gary wilson 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

When scrolling through a large program it can be difficult to find where you are in the program, even when clicking through bookmarks.

Colour coded markers on the scrollbar might help find bookmarks/breakpoints etc.

+1

Variable tolerance on scans/analysis view

gary wilson 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Some drawings show a gradual transition between profile tolerances but I'm currently unable to show this in a CMM report.

+1

Wind Chill CAD management option

Kingsld1 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Add the ability to work with Wind Chill cad management.   At least around here, Team Center is dying. 

+1

Circle evaluation with constraint

Sonny Setyawidjaya 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Found the constraint on radius/diameter of Circle, but need the constraint activated on the center of circle, to calculate actual radius/diameter on very small portion of circle.

+1

Option to remove Datum feature with MMC from report

Jonny 7 years ago in Metrology Software / PC-DMIS updated by Rob Jensen 4 years ago 1

When reporting features to Datums with MMC, the position of the features measured tend to always be zero, while the Datums the features are referenced to have a measurement? why is this? can the datums not be removed so only the features being measured show a measured value.

Image 79

+1

Collision List Improvement

Kingsld1 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 2

After Collision Detection has been run have only the Feature ID's on the Collision List appear on the Graphics Display Window.    This will cut down the amount of searching for a feature that occurs.  


Better yet, have collision detection automatically run as you offline program.

+1
Under review

One password to access all Hexagon websites.

Filips 7 years ago in Metrology Software updated by neil kay 5 years ago 2

One password to access all Hexagon websites.

+1

Scan segment construction from CAD surface

michael lee 7 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 2

Instead of clicking start/end points for a scan segment to construct a feature, I would like to be able to click a CAD surface so that all hits that cross that surface are included in the feature construction

+1

Recalculate actual values of measurements after probe qualification

jleond 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

PC-DMIS ability to recalculate actual values of current measured values in case of probe re-qualification, i. e. when using a probe angle that wasn't qualified a long time ago and it was used in a routine that takes a long time to run.