Lower matrix

Bill Kulpa 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Add a field in the lower level matrix calibration dialog box which informs the technician when the last time the lower matrix cal was performed.

+1

Bookmark location markers on scrollbar

gary wilson 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

When scrolling through a large program it can be difficult to find where you are in the program, even when clicking through bookmarks.

Colour coded markers on the scrollbar might help find bookmarks/breakpoints etc.

+1

Variable tolerance on scans/analysis view

gary wilson 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Some drawings show a gradual transition between profile tolerances but I'm currently unable to show this in a CMM report.

+1

Wind Chill CAD management option

Kingsld1 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Add the ability to work with Wind Chill cad management.   At least around here, Team Center is dying. 

+1

Circle evaluation with constraint

Sonny Setyawidjaya 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 0

Found the constraint on radius/diameter of Circle, but need the constraint activated on the center of circle, to calculate actual radius/diameter on very small portion of circle.

+1

Option to remove Datum feature with MMC from report

Jonny 8 years ago in Metrology Software / PC-DMIS updated by Rob Jensen 5 years ago 1

When reporting features to Datums with MMC, the position of the features measured tend to always be zero, while the Datums the features are referenced to have a measurement? why is this? can the datums not be removed so only the features being measured show a measured value.

Image 79

+1

Collision List Improvement

Kingsld1 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 2

After Collision Detection has been run have only the Feature ID's on the Collision List appear on the Graphics Display Window.    This will cut down the amount of searching for a feature that occurs.  


Better yet, have collision detection automatically run as you offline program.

+1
Under review

One password to access all Hexagon websites.

Filips 8 years ago in Metrology Software updated by neil kay 5 years ago 2

One password to access all Hexagon websites.

+1

Scan segment construction from CAD surface

michael lee 8 years ago in Metrology Software / PC-DMIS updated by neil kay 5 years ago 2

Instead of clicking start/end points for a scan segment to construct a feature, I would like to be able to click a CAD surface so that all hits that cross that surface are included in the feature construction