Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

Somehow mark Significant Characteristics (SC's) (CC's) on a report.

Jayson Woodard il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0
I would like to somehow make all the Significant Charateristics  stand out of the report without moving them out of balloon order. For example.. F1, F2, F3(SC), F4, F6(CC)....
0
Terminé

Default setting of the calculation type of the elements

Wolle il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par Matt il y a 4 ans 6

Currently, an elemente open always with the setting of the last use. 

But since most of the time is the default setting ASME or ISO 1101, it would be an advantage if this be can adjusted in advance. 

I would suggest here to insert an pullup meneu in the menu „NEW“ where the default setting of the elements can be preset.


0

Vision Auto Features - Percentage based enhancement

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Currently, when editing settings for vision auto features each segment is given it's own setting, clicking back and forth between options or un-segmenting and editing then re-segmenting is your only option.  It would be nice to check all features for editing or just certain features for editing.

0

Vision Auto Circle - Start/End position enhancment

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Currently, if i'm running percentage based vision circles, I have to guess and check between settings to align gears to teeth while maintaining all of the appropriate settings.

Allow the start and end positions to increment simultaneously by a degree while maintaining settings.

0

Vision Circles - Percentage improvement

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Currently vision segments are restricted to manual segmenting or a generic 10% percent based increment.

Problem - Gear circles often have in excess of 20 teeth and percentages do not line up with arc length of given teeth.

Solution allow percentages in increments of 1%

0

Variable focus - Vision / Focus Plane

Kyle Brummans il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 1

It would be nice to support a quick focus where I can set an intial amount of pre-focus at a lower mag then fine-tune the focus in high-mag - in one feature.  Similar to re-measure of a circle.

It would also be nice to have a quick focus feature incorporated into an auto plane where either the first point, three points, or all points have that ability.  Rather than multiple alignments, several times.

0

iso or asme Tangent point tolerance

michele pastore il y a 5 ans dans Metrology Software / TubeShaper mis à jour par neil kay il y a 5 ans 0

Exist the table? 

thanks

0
Terminé

Add a key in the quick Measurement Strategy Widget where you can difine samble hits .

Spring il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 1

Add a key in the quick Measurement Strategy Widget where you can difine samble hits ,for now it can't change the sample hits in PC-DMIS R2 with just 0 spacer. Or allow the programer change the hits position manually with the intuitive path line displayed.