Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+5

Provide tolerance zone visualization

Kesumm il y a 6 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Show tolerance zone visualization with DRF animation of GDT constraints

+5
Terminé

Add a Calibration Timer that Forces Tip Calibration through Inspect

Chris Fleshood il y a 6 ans dans Metrology Software / Inspect mis à jour par neil kay il y a 4 ans 8 1 doublon

Add a Calibration Timer that Forces Tip Calibration through Inspect

+5

PC-DMIS in one language, the report in another

Jörgen Andersson (vpt se) il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

I am running PC-DMIS with swedish language setting and thus, the report is also in swedish. However, it would be optimal if I could change the report template language to english - just for the report as we have customers all around the world.


In order to that today, I'd have to either run PC-DMIS in english (all the time) or change language, start PC-DMIS, open my program and print the report.


Would it be possible to add the possibility for the report templates to use a different language (other resources from the .dll's) template only for printing?

+5
Terminé

Need Square Tubing!!!!

Scott Martin il y a 7 ans dans Metrology Software / TubeShaper mis à jour par anthony vianna il y a 3 ans 4

Been begging for square tubes since TubeShaper came out.  I have many customers asking for this.

+5
À l'étude

Add bent tube to straight tube capabilities

Joe il y a 7 ans dans Metrology Software / TubeShaper mis à jour par neil kay il y a 5 ans 2

I measure a lot of bent tubes with copes (fish mouth cuts) on the ends of the tubes.  Would like to have the capability in TubeShaper to take  a measured bent tube (with measured cylinders on each end) and convert it to a straight state with the measured end cylinders in the correct orientation.  Then the straight tube can be exported as a CAD model so it can be used in a tube laser machine.

+5
À l'étude

Additional method for measuring long tubes (leap-frogging)

George Koskinas il y a 8 ans dans Metrology Software / TubeShaper mis à jour par neil kay il y a 5 ans 1

Currently the only method available for measuring long tubes (leap-frogging) is the "Move Tube" where it is required to measure two straights. If all straights are just too big to allow for selection/measurement of any two, this obviously won't work. Perhaps we can add an additional method, similar to that of G-Tube, where we add a displacement T-square, perpendicular to any straight.

+5

Continuing development of Textonly Legacy Reporting

Simon Prodan il y a 8 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 2

To have Legacy Textonly report supporting PC-DMIS Dimensions functionalities, or to have a similar report that is true text report and not just pictures that look like text.

+5
Terminé

Datum definition allow multiple characters

Valentin Tarba il y a 8 ans dans Metrology Software / PC-DMIS mis à jour par Rob Jensen il y a 5 ans 14 1 doublon

Allow to add multiple characters on a datum definition not only 2.

Image 22

+5
Terminé

New point construction method: "high point"

dave amstutz (djams) il y a 8 ans dans Metrology Software / PC-DMIS mis à jour par Neil Ryan il y a 12 mois 2

Finding the "high point" of a feature or scan is a very common measurement task.


In pc-dmis, this is a complex task, that requires an understanding of array indexing, and significant manual entry into a generic feature. It is prone to error, is very time consuming, and for users never exposed to a programming language it's a complete non-starter.


A simple, interface-based point construction method could be added to address these issues. The new method should be based on the DMIS method "CONST/EXTREM". It is very complete, and since pc-dmis imports DMIS code - it only makes sense to have a 1 to1 mapping of the DMIS definition.