Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+6
Terminé

DRF feature construction option(s) - relative to other features/datums

Jon Wood (NinjaBadger) il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 19 1 doublon

Add options to construct Datum features in such a way that they reflect the standard.


Example - Datum A is a Plane, and Datum B is a cylinder bore nominally perpendicular to the plane.


As per both ISO and ASME standards, Datum B would be a Max Insc Cylinder Perpendicular to Dat A.


It's easy enough to construct a Max Insc cylinder, but this wouldn't be forced perpendicular to the plane, currently you'd have to measure it as a series of circles, then construct a Max Insc Circle in the correct workplane after levelling to Dat A.


See bottom image for example (image shows shaft not bore but principle is the same).


Image 7


Like wise construct a datum plane from a measured plane relative to another feature (Top image)

+6

Make it possible to re-enumerate feature numbers after program is written/edited.

hellcatrydr il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par Neil Challinor il y a 7 mois 1

Your program is finished but some points or features were added and their out of numerical order.

A Re-number feature would put them all in ascending order.

+5

Save the PC-DMIS version/SP/Schema so that we can identify what version of PC-DMIS is needed to open this file.

Matt Beecher il y a 1 an dans Metrology Software / PC-DMIS mis à jour par Neil Challinor il y a 7 mois 2

Can we get some way to record what version/schema of PC-DMIS is required to open a particular PC-DMIS file?  With the rolling cutoff and some users having a mix of schema for their routines, I fear difficulties with using the migration utilities in the future. 

+5

Have the clearance cube wrap around the form of the part instead of a cube that has deadspace in it

Richmond il y a 2 ans dans Metrology Software / PC-DMIS mis à jour par Daniel Sylvester il y a 12 mois 1

This would save lots of time for some parts. Think of it like the shield from the Dune movies. The clearcube should form around the part

+5

Show constrained degrees of freedom in the geometric tolerance dialog window

Jacob Cheverie il y a 3 ans dans Metrology Software / PC-DMIS mis à jour il y a 3 ans 4

It would be helpful to see the actively constrained degrees of freedom as the feature control frame is being built in the geometric tolerance dialog window. As an example, assume I have a primary datum plane (normal Z+), a secondary datum cylinder (axis along Z), and a tertiary datum cylinder (axis along Z). Then, as I build my feature control frame, the geometric tolerance dialog window shows me which degrees of freedom become constrained as the images below show: 

Image 548

Image 549

Image 550

Image 551

+5

Compare PC-DMIS programs side by side

Ben Powell il y a 4 ans dans Metrology Software / PC-DMIS mis à jour par Jörgen Andersson (vpt se) il y a 3 ans 3

Ability to have two PC-DMIS programs open side by side/one on each monitor to compare and copy and paste between them.

Alternatively, a PC-DMIS clipboard you can use to copy and paste code to and from. 

+5

Ability to Assign a Dimension as Attribute

JIM il y a 4 ans dans Metrology Software / PC-DMIS 0

I would like the ability to create an attribute dimension, similar to a "Keyed In" dimension that has a non-numerical value of either "PASS" OR "FAIL" and the ability to pass that result to reports or Excel exports.  Currently, all defined dimensions are numerical.

+5

Complete autocalibration routine

Hunter il y a 4 ans dans Metrology Software / PC-DMIS 0

Autocalibration Currently does not remeasure failed tips. My suggestion is to implement a feature within the Autocalibration routine that allows it to remeasure the tips that failed the standard deviation. As well as adding a feature within the autocalibration code that allows you to select the calibration sphere when the qualtool has been moved only. This would be used for all autocalibration within that code as well but only selected at the beginning of the program to ensure correct vector and size are used. My expectation if this gets implemented is when i leave on Friday, i can start the autocalibration routine and come back on Monday with no tips that have been outside of the standard deviations.

+5

Gerber Format Support

frank herr il y a 4 ans dans Metrology Software / PC-DMIS mis à jour il y a 4 ans 1

The Gerber format is a standard ASCII format file structure and uses X, Y, Z and I, J, K information that enables data exchange between CAD (development) and CAM (production). It is primarily used in electronic CAD programs (EDA – Electronic Design Automation) to output layout data for printed circuit boards.

We are frequently confronted with this format and here we have a competitive disadvantage compared to providers who can read this format into their measurement software without further external conversion.

It would therefore be desirable to integrate a corresponding import interface into PC-DMIS.

+5

Color code for tolerances

ATT-Danilo il y a 4 ans dans Metrology Software / PC-DMIS mis à jour par J Grijsen il y a 2 semaines 2

I suggest the software recognizes the color of the surfaces the points are applied to.

When we create dimentions, instead of adding the tollerance for each point (or group of points), we select a color code (that has been sorted out by our engenieering department) and the tolerances are applied considering the CAD surface color and which tolerance that color represents on my color code.