0

Somehow mark Significant Characteristics (SC's) (CC's) on a report.

Jayson Woodard hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 0
I would like to somehow make all the Significant Charateristics  stand out of the report without moving them out of balloon order. For example.. F1, F2, F3(SC), F4, F6(CC)....
0
COMPLETADO

Default setting of the calculation type of the elements

Wolle hace 5 años en Metrology Software / PC-DMIS actualizado por Matt hace 4 años 6

Currently, an elemente open always with the setting of the last use. 

But since most of the time is the default setting ASME or ISO 1101, it would be an advantage if this be can adjusted in advance. 

I would suggest here to insert an pullup meneu in the menu „NEW“ where the default setting of the elements can be preset.


0

Vision Auto Features - Percentage based enhancement

Kyle Brummans hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 0

Currently, when editing settings for vision auto features each segment is given it's own setting, clicking back and forth between options or un-segmenting and editing then re-segmenting is your only option.  It would be nice to check all features for editing or just certain features for editing.

0

Vision Auto Circle - Start/End position enhancment

Kyle Brummans hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 0

Currently, if i'm running percentage based vision circles, I have to guess and check between settings to align gears to teeth while maintaining all of the appropriate settings.

Allow the start and end positions to increment simultaneously by a degree while maintaining settings.

0

Vision Circles - Percentage improvement

Kyle Brummans hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 0

Currently vision segments are restricted to manual segmenting or a generic 10% percent based increment.

Problem - Gear circles often have in excess of 20 teeth and percentages do not line up with arc length of given teeth.

Solution allow percentages in increments of 1%

0

Variable focus - Vision / Focus Plane

Kyle Brummans hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 1

It would be nice to support a quick focus where I can set an intial amount of pre-focus at a lower mag then fine-tune the focus in high-mag - in one feature.  Similar to re-measure of a circle.

It would also be nice to have a quick focus feature incorporated into an auto plane where either the first point, three points, or all points have that ability.  Rather than multiple alignments, several times.

0

iso or asme Tangent point tolerance

michele pastore hace 5 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 0

Exist the table? 

thanks

0
COMPLETADO

Add a key in the quick Measurement Strategy Widget where you can difine samble hits .

Spring hace 5 años en Metrology Software / PC-DMIS actualizado por neil kay hace 5 años 1

Add a key in the quick Measurement Strategy Widget where you can difine samble hits ,for now it can't change the sample hits in PC-DMIS R2 with just 0 spacer. Or allow the programer change the hits position manually with the intuitive path line displayed.