CAD Section cut dialog should have a default preview turned off. Or add option to AutoPreview
The CAD Section cut dialog always starts sectioning before a user has any opportunity to defined method, location, size of section, etc. Depending on the CAD model complexity, the current units and PC, it can mean a very long wait on the dialog. Also, as user makes changes, every change refreshes. I suggest a checkbox that defaults to Off for preview of resulting section. Kind of like on our Designer software. You can choose to have preview always active or not.
best way to report +/- material on individual points on a constructed circle
best way to report +/- material on individual points on a constructed circle
Allow move points in only 1 or 2 axis in Summary Mode
While programming in Command mode, If you inserted a move command:
MOVE/POINT,NORMAL,<0,0,5>
Then delete the axis that you don’t want to move
MOVE/POINT,NORMAL,<,,5> (This will move only the Z axis to 5 above the current alignment.)
Once we write a program, our shop floor uses protect mode on the CMMs to keep the programs from being messed with. Protect mode automatically enables summary mode.
According to the PCDMIS help file, when summary mode is turned on, PCDMIS will override this setting and move the XY coordinate as well.
|Pasted below from the Help File. Link is also below. Paragraph is at the bottom of the article|
Moving In Only 1 or 2 Axes
In the Edit window in Command mode, you can set one of the axis values to blank (which means that you completely delete the value) to give the axis a relative move of zero during measurement routine execution. This essentially lets you have a hybrid relative and absolute move point behavior using the MOVE/POINT command.
This feature only works fully in Command mode. If you use Summary mode to do this, the field disappears from the Edit window. If you want to then set it back to a number value, you need to set it in Command mode.
As an alternative to this post, could we have a Command mode view, yet still keep protect mode on? Whichever would be easier in my opinion.
Quickly turn on and off pathlines?
Could a shortcut key be created or a quick button to turn on and off pathlines in a program?
some terminology mistakes in Chinese version
In the Chinese version, the following terminologies do not match the Chinese national standard:
English terminologies Feature Plus Tolerence Minus Tolerance | Terminologies in Chinese PC-DMIS 特征 上公差 下公差 | Terminologies in GB 要素 上极限偏差 下极限偏差 |
Separate scanning parameters from probing parameters
When changes are made to scan parameters such as point density
all other probe parameters are also automatically entered in the program.
However, if parts are measured with different measuring machines but the same program, the stored probe parameters must not be changed.
As this is not possible, the probe parameters must be adjusted each time in the program.
Scanning parameters should therefore be separated from the probe parameters, as is the case in other areas.
PCDMIS admin panel
Hello PCDMIS gurus and devs.
I would appreciate if PCDMIS had admin panel where I could define all settings once and then point this admin panel to every computer where installation of PCDMIS exists this way If I wanted to change say for example speed of all machines or some other generic settings it would be done from one panel. For example layout of buttons, speed of 3D CMM, loading colors for highlighting code etc.