Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+3

hotkey for find and replace

louisd il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 3

ALT+F3 is the find Hotkey, how about a hotkey for Find and Replace?

+3

Using the Adaptive Scan Strategy to improve scanning speed!

Montage Zhang il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 1

Image 18

Image 17

Image 19

Image 20

+3

Simulation Speed - able to change it during the simulation

wayne branton il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par Neil Challinor il y a 10 mois 1

It would be nice to vary the simulation speed during offline program by either using the keyboard arrow keys or the speed setting on the jogbox - that way you can slow it down or speed it up on the fly only when you need it to without having to invoke the speed change thru a menu, etc.

+3

Add formulas to all Text boxes (with Assignments)

JVP il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 2

Make X/Y/Z/I/J/K/Dia/etc have the ability to accept and recognize formulas (and variables/Assignments). After entering the formula it should stay active/visible for easy editing in the future.

+3

Change the generic feature creation to include a drop down selection of previously measured features

banjopkr61 il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 0

Change the generic feature creation to include a drop down selection of previously measured features such that you could select PLN1.TX - Cir2.TY - Line3.TZ and PLN1.X - CIR2.Y - Line3.Z to populate the new generic feature as you create it.

+3

Error messages should begin with a distinct identifying alpha-numeric code to provide a simpler means of referencing them. Otherwise, some errors messages have similar text and can be confused.

Chuck il y a 10 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 6 ans 0

Error messages should begin with a distinct identifying alpha-numeric code to provide a simpler means of referencing them. Otherwise, some errors messages have similar text and can be confused.

+3
Terminé

I would like to see the Live Image view so I can use INSPECT on a vision machine, and use the view to do the manual alignment features

neil kay il y a 10 ans dans Metrology Software / Inspect mis à jour il y a 6 ans 7

At the moment, INSPECT is not very useful for Vision machines, as without seeing the camera view, then the manual alignment features are impossible to position.

+2

Thread Pitch Selection

J Rys il y a 2 mois dans Metrology Software / PC-DMIS mis à jour par Guillermo il y a 2 mois 1

It would be helpful to add a dropdown menu for thread pitch selection instead of requiring users to manually type in the pitch for each thread. The dropdown could include common inch and metric thread sizes, along with an option for LH threads, allowing users to quickly select the correct pitch from a list.  This would save time and make the thread creation process more consistent and user-friendly

+2

Vision - I would like a switch to save ALL images captured by the camera during a program run

natanderson il y a 4 mois dans Metrology Software / PC-DMIS 0

In PCDMIS-Vision I would like a switch on/off setting to generate all images captured by the camera during a program run including the display of the measured points. This raw vision data would be extremely useful for root cause analysis.

It would be similar to the existing Diagnostics tool but available in run mode and not requiring to be turned on for each feature. Vision images tell the story of the measurement and are invaluable for troubleshooting and to support cross-sites communication.

+2

Separate PCDMIS installation and license requirement. This is not suitable for enterprise roll-out. License details could be a requirement at runtime.

Mike Donnan il y a 4 mois dans Metrology Software / PC-DMIS 0

Current installation mechanism requires local login to PC.

This is time consuming and prevents parallel deployment.

Silent installation is documented... but still requires license and local login ?