Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+2
En revisión

Spring Back Value not to be applied to 1st Straight

Liviu hace 6 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 2

After calculating and saving the Spring Back Value we can use this calculations to correct the LRA of a new nominal tube.

The only thing that TubeShaper is applying the spring back correction to the 1st straight.

This is the only straight that has no elongation error, because  the rotation and the bending angle are applied from the second one forward. Actually the TS is correcting the tube on the 1st straight, and after the 1st measurement he bring's it back close to the nominal. 

If we don't apply SPE correction on the 1st straight, the customer has to do 1 correction less and he has 1 less scraped tube.

+2

CALRA

Alexander Schneeberger hace 6 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 0

Switching from LRA- to ALRA-values is possible just by one click. Not for the corrected values. For those of us who work with ALRA-values, this would be crucial to use the full  functionality of TubeShaper. thanks

+2
Denegado

Make a way where you can rename the project easily. i.e right click then rename project.

mthomas hace 6 años en Metrology Software / TubeShaper actualizado por anthony vianna hace 3 años 2

The only way to rename the file is to save as then delete the old one. There should be a way to right click then rename the project like you can do with normal files in Windows Explorer.

+2
Denegado

Add tools button to reverse engineer tube section

michael mazzaferri hace 7 años en Metrology Software / TubeShaper actualizado por anthony vianna hace 3 años 1

Can we get a tools button that take the user to the tools area to measure a tube bend radius and dia instead of having customer close out of reverse eng screen to get bend rad and dia.

+2
COMPLETADO

Add image import capability for comments

Jordan hace 7 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 1

It would be nice to add images to comments in TubeShaper (like in PCDMIS).  Especially to help with setup instructions for operators.

+2
En revisión

Total bend and total rotation

rtomsu hace 7 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 4

I would like to see the sum of bend angles and the sum of bend rotations in report. Nominal values.

+2
En revisión

Add IP point distances

sebastiaan kuiper hace 7 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 2

Add an option to have a table in the report showing 3D distances between Intersection points.


IP1 > IP2

IP2 > IP3

etc

+2
COMPLETADO

Change the coloring of the coordinate system to the conventionally used XYZ=RGB.

George Koskinas hace 7 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 1

The currently-used coloring, XYZ=BGR, is very confusing for most 3D CAD software users.

+2
En revisión

Projects listing area - ability to support folders (file explorer)

George Koskinas hace 8 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 1

For efficient file storage and organization. Currently the only way to keep projects organized (i.e. by customer name, tube identification, tube family, etc) is to give them very long titles/filenames.

+2
En revisión

Report options should be applied to exported text (csv) file too.

George Koskinas hace 8 años en Metrology Software / TubeShaper actualizado por neil kay hace 5 años 2 1 duplicado

The report options are currently applied to (1) the built-in saved report, (2) the exported-to-PDF report, and (3) the direct print report. They are not applied to the export-to-CSV report, which contains the full data regardless of the report-options selected.