Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+2

CALRA

Alexander Schneeberger 7 jaar geleden in Metrology Software / TubeShaper bijgewerkt door neil kay 5 jaar geleden 0

Switching from LRA- to ALRA-values is possible just by one click. Not for the corrected values. For those of us who work with ALRA-values, this would be crucial to use the full  functionality of TubeShaper. thanks

+2
Declined

Make a way where you can rename the project easily. i.e right click then rename project.

mthomas 7 jaar geleden in Metrology Software / TubeShaper bijgewerkt door anthony vianna 4 jaar geleden 2

The only way to rename the file is to save as then delete the old one. There should be a way to right click then rename the project like you can do with normal files in Windows Explorer.

+2

Generic feature “link”check box

tbd 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0

Would be great to have to option to have a check box that if checked whatever settings you type in under the actual’s tab would also populate the data fields in the nominal s tab. Also to go a step further if the programmer had the ability to click “select” an already created featurs that the generic feature utility would be able to recognize and extract X,Y,Z, and I,J,K’s dia ect… and or drop down list of previously created features.

+2

Add "marked used" parameter set option to AutoCalibrate/Probe command

Kingsld1 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0

Add a 'mark used' parameter set option to the Autocalibrate/Probe command.


Basically I'd like the LoadProbe, Mark used, Measure sequence to be automated.   


I've never created a calibration parameter set that wasn't created from the marked use checkbox on the load probe command.  It's hard to imagine a case where I wouldn't do this unless I wanted to recalibrate an individual probe under program control.


Doing this could eliminate the possibility of forgetting to update the Parameter set when the measurement routine is updated. 



+2

PC-DMIS Customize process needs a total rebuild

davehocum 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door Jörgen Andersson (vpt se) 3 jaar geleden 10

PC-DMIS Customize process needs a total rebuild. Example: The User Defined Commands that will create numerous copies of the same customize commands. This has been an ongoing problem for years now. And a much needed improved workflow is a must.


Image 179

Here is an example. Look at the caption below and you can see that there is two Move Feature commands.

Image 180


I have lots more examples if needed.



+2

Multiple part execution with toggle instead of having to code loops

Lupe Chavez 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 1
+2

Multiple part reporting

Trevor McLaughlin 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0

I'd like to be able to report multiple runs of a part within pcdmis. 

+2

Ability to quickly change sizes of ID's in graphics window

craig 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0
+2

I want PCDMIS to create perfect paths with no collisions always

Ken Woodbine 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0
+2

Basic dimension added to profile with form and location.

Todd 7 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door neil kay 5 jaar geleden 0

when doing a profile with form and location add a check box for the basic location.