Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+1

Simultaneous Tolerance command - Filter list on truly different datum features, not just the name.

Jacob Cheverie 5 måneder siden i Metrology Software / PC-DMIS 0

When entering a new simultaneous tolerance command, there is a "smart" filter in which dimensions that don't share the same datum reference frame as the first selected dimension will be removed from the list. The filtering seems to be based on the datum letter(s) itself and not the actual datum features used within the DATDEF command.

Example: A part is measured, flipped halfway through, and measurement is finished. In both orientations, the same datum feature was measured (measured twice). When creating dimensions, DATDEF commands are inserted at the appropriate location, redefining the datum required for measurement (datum feature pre-flip, datum feature post-flip). The Simultaneous Tolerance command will show all of the dimensions in the dialog window after auto-filtering, but selecting all the dimensions will result in an error "Simultaneous tolerances must have identical datum reference frames." because the datum features are technically different in each dimension (pre-flip vs post-flip).

Please investigate the feasibility of changing the filtering rules of the Simultaneous Tolerance command by looking at the actual features used in the DATDEF command, and not just the letter(s) assigned.

Thank you.

+1

Have PC-DMIS save mid program automatically

Richmond 6 måneder siden i Metrology Software / PC-DMIS opdateret af Yuan Ren 4 måneder siden 4

When running larger programs in PC-DMIS on my computer, if I have any kind of error the software usually freezes then closes on me. Would it be possible to have the software save periodically in the background while its running. Right now I stop the program 3-5 times to save it so if it crashes I dont have to start from the beginning.

+1

Add cylindrical line profile tolerance evaluation (for pipes/tubes)

I would love to have the possibility to evaluate cylindrical line profile tolerances, especially used on tubes/pipes.

Example:

Image 622

Often (but not always) used with a coordinate table:

Image 623

...and a bending radii:

Image 624

With this information, we can create a pipe centerline (if we don't have CAD) to use as nominal.

I have already checked the other Hexagon software offerings, such as BendingStudio and TubeShaper and they cannot evaluate this. The application manager for BS even told me that BS cannot and will not be able to evaluate this. BS is for manufacturing - not metrology.

AFAIK, no software on the market can evaluate this, except for PC-DMIS and Metrolog - with the help of an external program made by Hexagon Metrology Nordic called JoTube2. However, this program is no longer under active maintenance and hasn't been updated since 2013, probably due to low sales (and the author retired). This means that we need to find a solution to this problem as the software is slowly decaying due to OS upgrades and soon we won't have the luxury of being able to use it.

The two largest truck companies in Sweden are using this line profile tolerance for their pipes, I am unsure of other manufacturers. This means that the suppliers to them are suffering from the same problem - no proper evaluation method...

Line profile is mainly 2D, but ISO 1101 points to ISO 1660 that states that line profile tolerance zone can be made cylindrical by preceding the tolerance value with Ø.


Please consider to include this to PC-DMIS, either as an option or a standard feature!

+1

Summary and command mode taskbar button

Joanna P 6 måneder siden i Metrology Software / PC-DMIS opdateret af Wes77 6 måneder siden 1

Addition of a taskbar button to switch between summary and command mode easily

+1

Adding comment to assign command

Mick Hinton_53 8 måneder siden i Metrology Software / PC-DMIS 0

You should be able to add a comment to the end of an assign line of code.

For example, currently the code is

ASSIGN/V1=10

it would be good if you could add a comment at the end to help with editing the program by adding $$ at the end, example

ASSIGN/V1=10 $$ diameter of hole 1

ASSIGN/V2=20 $$ diameter of hole 2

+1

Visual indicator for scan control points

zachr 8 måneder siden i Metrology Software / PC-DMIS 0

When trying to add control points it is very difficult to understand what the control point is actually doing or when it will trigger. If there could be some sort of visual aid that shows the control point along the scan path that would be very helpful.

+1

Excel Form Report, PCD ID |x||y||z| output

MikeA. 10 måneder siden i Metrology Software / PC-DMIS opdateret af Sudhanshu Trivedi 10 måneder siden 9

In excel form report, can we implement where the xyz values will run in a row for a dimension, and than in the next row below it another dimension and it's xyz values, and so on and so forth. 

Example:

Row1: |X|,|Y|,|Z|,|PCD ID|

Row2: |X|,|Y|,|Z|,|PCD ID|

Row3: |X|,|Y|,|Z|,|PCD ID|

etc.

+1

Locking a feature label to

Richmond 10 måneder siden i Metrology Software / PC-DMIS 0

I would like to be able to select feature labels to stay in the view in the camera while dimensioning. For example if the part is really big but all the dimensions come from Datum A it would be nice to have the datum A feature label always in the camera view to easily select it. Right now can drag the label around but this would be much easier.  The same way we can lock and unlock targets on the vision systems