Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+2

Xact Measure Report

jodische 6 år siden i Metrology Software / PC-DMIS opdateret af Rob Jensen 4 år siden 4

Make Xact measure report easy to re-arrange so it looks like the Legacy Report.  You can shutoff and turn on whatever you want to go to the printer or stats (in whatever order you want) .  In machining all the machinist cares about is which way they need to move the machine.  All they want to see for Position for example is X, Y, Diameter Size and Position.  They do not want to see datum shift, the position of the datum's you used, the size of the datum used.  The Report is to long and confusing and out of order.

+2
Færdig

Warning on what options are available with different version of Pcdmis

davehocum 6 år siden i Metrology Software / Inspect opdateret af neil kay 4 år siden 5

Just finish testing Inspect 3.2. Back saved a 2018 R1 routine to 2017 R1. Closed Pcdmis and open Inspect 3.2. Installed the 2017 R1 add-on. Open the routine using Inspect 3.2 and executed the routine. First warning that the saved default Report template Text and Cad.rpt serialization error. Report template from later version. Nice, then I selected OK and waited for the Pcdmis startup and wait and wait. Finally execution is at 6% then a pause. Forms will not show and there is no CAD window selection either. Let's try 2017 R2. Same issue. Let's try this using 2018 R1 and the forms work as expected. The CAD selection is available now. There should be a warning on what options are available with different version of Pcdmis.

+2

Xact Measure GD&T axis

rtomsu 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

Make possible to set which axis will be displayed in report by default. At this time when I use Xact Measure GD&T almost all axis are selected but I dont want them in report so I need to unselect them all except for those which must be displayed. I need to do that at every single GD&T result but when you change just one alignment all axis will select again and I need to do all the work again and again. It is really annoying. 

+2

Add move/clearcube (Even within auto features and scans.)

Derek 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

In the older versions of PC-DMIS; prior to clearance cube, when using clearance plane you could simply type "move/clearplane" within a non auto feature and if would clear the plane and stay there until it was time to take the next hit. Clearance cube is a superior tool in most regards but I have to add move/points when ever I want to deviate from the path. I would like to have the same kind of thing with the cube; It would be very helpful to have the ability to clear the cube when ever I see fit. Even within auto features and scans. Please ask if you would like me to better clarify.

+2

Ability to close Inspect Launcher

davehocum 6 år siden i Metrology Software / Inspect opdateret af neil kay 5 år siden 5

Ability to close Inspect Launcher
Ability to close Inspect Launcher before the launcher opens Inspect.

+2

able to get machine id by a command when PC-DMIS running on that computer

THAO HUYNH 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 3

it helps when the same program run on different machine that i can know which machine they run on my report and able to make some adjustment per machine type.

+2

CALRA

Alexander Schneeberger 6 år siden i Metrology Software / TubeShaper opdateret af neil kay 5 år siden 0

Switching from LRA- to ALRA-values is possible just by one click. Not for the corrected values. For those of us who work with ALRA-values, this would be crucial to use the full  functionality of TubeShaper. thanks

+2
Afvist

Make a way where you can rename the project easily. i.e right click then rename project.

mthomas 6 år siden i Metrology Software / TubeShaper opdateret af anthony vianna 3 år siden 2

The only way to rename the file is to save as then delete the old one. There should be a way to right click then rename the project like you can do with normal files in Windows Explorer.

+2

Generic feature “link”check box

tbd 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

Would be great to have to option to have a check box that if checked whatever settings you type in under the actual’s tab would also populate the data fields in the nominal s tab. Also to go a step further if the programmer had the ability to click “select” an already created featurs that the generic feature utility would be able to recognize and extract X,Y,Z, and I,J,K’s dia ect… and or drop down list of previously created features.

+2

PC-DMIS Customize process needs a total rebuild

davehocum 6 år siden i Metrology Software / PC-DMIS opdateret af Jörgen Andersson (vpt se) 2 år siden 10

PC-DMIS Customize process needs a total rebuild. Example: The User Defined Commands that will create numerous copies of the same customize commands. This has been an ongoing problem for years now. And a much needed improved workflow is a must.


Image 179

Here is an example. Look at the caption below and you can see that there is two Move Feature commands.

Image 180


I have lots more examples if needed.



Kundesupport af UserEcho