Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

+1

CAD model Export

Mitja Smrekar il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

I have a program with a CAD model in it, but I do not have a model in any other CAD format (stp, igs, prt...) only .cad from PC-DMIS. I need a function to export CAD model from PC-DMIS to other formats like stp and igs.


Situation is: I have only a PC-DMIS program and I need a model because we can not find that model anywhere.

+1

Separate Clearance Cubes = More efficient probe travel times.

Derek il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 3

When I import my 1-2-3 blocks for fixturing or whatever I bring in, I would like each of them to be able to have their own clearance cube instead of having to have a large cube encompassing the whole set up.  Sometimes with larger fixtures it would definitely speed things up if the probe didn't think it had to move so far away from my part just because the constraints of the CC are limited to the overall size of my imported fixturing.  And why stop there, also make it where if I don't have a fixture model I can manually set up a cube just for that single fixture piece as well.

+1

more information in the calibration results window

Aaron Baldauf il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Add more information to the calibration results window like: touch speed, scan speed, move speed, prehit/retract distance and so on. It would help to decide if the calibration has to be done again because of differences in these settings.


Here's an example:

Image 95


+1

Clearance cube around probe changer

Bill Kulpa il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Add something like a clearance cube around a probe changer if desired.

Basically like a saftey zone around the rack so that someone cant run probe, probe head, z rail into it while running a program.

+1

Lower matrix

Bill Kulpa il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Add a field in the lower level matrix calibration dialog box which informs the technician when the last time the lower matrix cal was performed.

+1

Bookmark location markers on scrollbar

gary wilson il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

When scrolling through a large program it can be difficult to find where you are in the program, even when clicking through bookmarks.

Colour coded markers on the scrollbar might help find bookmarks/breakpoints etc.

+1

Variable tolerance on scans/analysis view

gary wilson il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Some drawings show a gradual transition between profile tolerances but I'm currently unable to show this in a CMM report.

+1

Wind Chill CAD management option

Kingsld1 il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Add the ability to work with Wind Chill cad management.   At least around here, Team Center is dying. 

+1

Circle evaluation with constraint

Sonny Setyawidjaya il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 5 ans 0

Found the constraint on radius/diameter of Circle, but need the constraint activated on the center of circle, to calculate actual radius/diameter on very small portion of circle.

+1

Option to remove Datum feature with MMC from report

Jonny il y a 7 ans dans Metrology Software / PC-DMIS mis à jour par Rob Jensen il y a 4 ans 1

When reporting features to Datums with MMC, the position of the features measured tend to always be zero, while the Datums the features are referenced to have a measurement? why is this? can the datums not be removed so only the features being measured show a measured value.

Image 79