+1

3D Connexion Space Mouse

Eric_Gagnon il y a 3 mois dans Metrology Software / PC-DMIS 0

Allow/Enable the Compatibility of the 3D Connexion Space Mouse (CAD Mouse)

+1

Mitutoyo Mcosmos Conversion

Dean Sadler il y a 3 mois dans Metrology Software / PC-DMIS 0

Converter to enable Mitutoyo MCosmos programs to run in PC-DMIS.

+1

Excel from Templates need to be able to be saved on a network location for multiple CMM.s instead of the local C: Drive for the template location.

Chris DeBoard il y a 3 mois dans Metrology Software / PC-DMIS 0

When pulling in a Excel from template, one should be able to direct the look up for the templates to a network location and not just the c: drive. In a company with multiple CMM's one would need to maintain a template on several CMM's hard drives instead on one network location to pull the template from. Can this be added in the next revision? 

+1

Remaining Travel + Next Action Display for CMM

dominik mayerhofer il y a 4 mois dans Metrology Software / PC-DMIS 0

I suggest adding a “remaining travel” and “next action” display for the 3D CMM, similar to what we have on CNC lathes and milling machines. This would give a clear overview of where the machine will move next, helping to avoid collisions and making it easier to follow what happens during program runs or teaching.

Thanks for considering this! Edit: I accedentally suggested this on Hardware so I wanted to resuggest it here too.

+1
Écarté

Datum modifiers for perpendicularity if datums are features of size

Nano il y a 5 mois dans Metrology Software / PC-DMIS mis à jour par Neil Challinor hier à 08:45 1

PC-DMIS doesn't allow datum modifiers for perpendicularity on features of size. we see this a lot and would like to see this capability added on.

+1

Dark Mode Enhancment

TMO il y a 7 mois dans Metrology Software / PC-DMIS 0

Dark Mode already exists in the software but really deserves to be expanded on. Currently just the home page and the GD&T menus are affected with dark mode. Dark mode should change the whole UI.

+1

Pointcloud Operator (select funktion)

dan brokstad il y a 7 mois dans Metrology Software / PC-DMIS 0

In select function menu I like to have a "multi select funktion".

So I don't need to reset the cloud every time I need several section.

Image 667

+1

Point cloud alignment

dan brokstad il y a 7 mois dans Metrology Software / PC-DMIS 0

Customers who manufacture plates for hydrogen fuel cells or heat exchangers usually want their tool halves to be aligned according to the following principle.

1. The tool is aligned with a probe.

2. Then it is scanned with a laser (HP-L-10.10)

3. A Refine alignment is performed with the point cloud.

4. A primary plane is extracted from the point cloud.

5. Aligns as Z primary and Z zero.

6. Evaluates

However, this procedure is not correct as the plane is not exactly parallel to the pattern!

Of course, you can extract points and use these for XY and Z rotation, or construct "alignment features", but I want to use all the points in the pattern area in a easy way.

What I want is more possibilities in the point cloud alignment so that I can control/adjust my alignment better.

+1

to points on all features

QCGroup il y a 7 mois dans Metrology Software / PC-DMIS 0

Can we have a 'to points' added on all features. 

would be helpful.

+1

Improving Program Traceability in PC-DMIS: Folder-Based Saving Strategy Inspired by PolyWorks

SiSkebab il y a 9 mois dans Metrology Software / PC-DMIS 0

It would be a good idea to configure PC-DMIS so that each measurement program is automatically saved in its designated folder. This improves traceability and makes it easier to retrieve previous measurement sessions for review or verification. For example, if I need to revisit a measurement I performed a few days ago, I can quickly locate the corresponding program and results.

Technically, this can be achieved by setting a default save path in PC-DMIS, either through the software preferences or by using a startup script. This ensures that all programs are stored in a structured and consistent way, reducing the risk of file misplacement or overwriting. It also supports better version control and simplifies data management, especially in multi-user environments.

This kind of functionality already exists in PolyWorks, where the software automatically organizes measurement projects into predefined folders, making it easier to manage and access historical data. Implementing a similar approach in PC-DMIS would bring significant benefits to workflow efficiency and data integrity.