Adding created views in Legacy report.

Mitja Smrekar vor 10 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 0

I wish I could insert created views in legacy report. Now I can only recall views and make a screenshot of screen and this is not automated. Creation of complete legacy report take too much time but creating views is simple and faster. Legacy report is saved as PDF document.

+1

The ability to drop photos into reports at the click of a button

Daren King vor 10 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 2

a quicker more accessible option for reporting

+1

Pattern Feature

Graham_Sam vor 10 Jahren in Metrology Software / PC-DMIS aktualisiert von neil kay vor 6 Jahren 1

We would like to be able to pattern around a specified feature as oppose to having to move the datum to that location, as pattern only operates around the datum.

0

Improve "Seach Path" with a "Group" field.

jmead vor 2 Wochen in Metrology Software / PC-DMIS aktualisiert von Wesley vor 2 Wochen 1

Image 696

Add a Seach Path "Group" field. I support programing for multiple sites and vendors off/online. Setting up a "group" search path would be a great help. Option to imbed search path in the program routine may be nice as well. Things get messy with 12+ sites/vendors. I can switch sites multiple times in a day.

0

Quindos Converter

Pedro Capela vor 2 Wochen in Metrology Software / PC-DMIS 0

Hello Everyone,

It would be great if it were possible to create a converter for Quindos programmes to PC-Dmis.

I have several clients who would switch software on the spot.

0

Dimension Visualization CAD & Maybe vision overlay

Guillermo vor 3 Wochen in Metrology Software / PC-DMIS aktualisiert vor 3 Wochen 1
0
Fertiggestellt

GD&T CAD & OCR Select feature creations should follow any active default MSE we use for QuickFeatures

Guillermo vor 4 Wochen in Metrology Software / PC-DMIS aktualisiert von Neil Challinor gestern um 08:31 5

Say I bring it a CAD model w/ embedded PMI (GD&T) or use the GD&T select from image option, features that are creating ignore any active MSE (default group) that would work with QuickMeasure.  This means, one has to edit the auto feature after the fact.  Same seems to be the issue if creating auto features using the toolbar and dialog.  They do remember what user last did, but they do not follow the MSE when creating new routines.  This also means that items like AutoWrist get ignored.  Only workaround I can find is to QuickMeasure create the feature first and then Click/use the GD&T callout.  If Assuming I have the correct feature type for the association. 

0
Fertiggestellt

Check that all features are reported.

Craig H vor 2 Monaten in Metrology Software / PC-DMIS aktualisiert von KAY Neil vor 4 Tagen 2

A way to check to see if you reported measurements on all features measured so you don't forget to report on them.

0
Fertiggestellt

Reopen a completed run without the physical part present

//Stocken vor 3 Monaten in Metrology Software / PC-DMIS aktualisiert von Neil Ryan vor 3 Wochen 2

I would like PC-DMIS to support a replayable measurement result package similar in functionality to ZEISS Calypso’s saved measurement data concept.
The purpose is to reopen a completed run without the physical part present, using stored measured points, constructed features, alignments, and run-specific evaluation data.

PC-DMIS already appears to generate interim or backup data between runs, which suggests an existing mechanism that could potentially be extended into a formal run snapshot / replay file.

This would provide major benefits for offline analysis, troubleshooting, reporting, training, reproducibility, and reduced machine occupation.

Ideally the stored package should include:

  • measured hit points / scan points

  • calculated features

  • active alignment and datum state

  • sensor context

  • timestamp / operator metadata

  • optional CAD link reference

The main goal is not full raw machine logging, but a practical, reopenable measurement dataset that allows re-evaluation without remeasuring the physical part.

0

Add VISI to the supported CAD formats in Replace Component

Wayne P vor 3 Monaten in Metrology Software / PC-DMIS 0

I would like to see VISI cad file support added to the Replace Component function in CAD Assembly.