White Light Scanning - Calibration - Calibration Offset

Anthony Fotion 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 0

Currently PC-DMIS does not have a way for a CWLS system to calibrate the offset within the probe utilities edit window. You can construct the probe but for calibration it requires a completely separate process. This would be for a Vision primary system with TTP & CWLS probe capabilities.

Currently I have 3 different CWLS lenses and 3 different Vision lenses.

In order to calibrate the offset between each possible configuration of lenses requires me to program a separate calibration routine for each configuration and then uses manually coded scripting to update the PRB.BAS file.

This would be a great thing to add.





+1

Automatic Indexing for Logic Functions when using Paste with Pattern

Anthony Fotion 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 1

This once seems simple but I have yet to find a work around. I am trying to extract data points from MANY scan sets and utilize paste with pattern to do so.


Unfortunately when trying to use this, paste with pattern will auto index everything EXCEPT the bold area, it will stay at SCN1 instead of 1, 2, 3 ect. like everything around it. Not sure why, and I am not sure if there is a way around it, if paste with pattern is not capable to do this I think it should be.

Thanks!

ASSIGN/HITN = MAXINDEX(SCN1.HIT[1..SCN1.NUMHITS].X)

ASSIGN/HITN = MAXINDEX(SCN1.HIT[1..SCN1.NUMHITS].X) 
ASSIGN/MAXVAL = SCN1.HIT[HITN].X
F1 =GENERIC/POINT,DEPENDENT,RECT,$
NOM/XYZ,SCN1.HIT[HITN].TX,SCN1.HIT[HITN].TY,SCN1.HIT[HITN].TZ,$
MEAS/XYZ,SCN1.HIT[HITN].X,SCN1.HIT[HITN].Y,SCN1.HIT[HITN].Z,$
NOM/IJK,0,0,1,$
MEAS/IJK,0,0,1
+1

White Light Scanning - Lens Range Changing - Edit Window Command

Anthony Fotion 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 2

Currently the way PC-DMIS is if you are using a Precitec type controller for a CWLS system in order to correct the range on the controller for the current lens of use you have to go in EGON Configuration editor (which you should not do unless you really know what you are doing! but I had to) to change the WLS Lens selection.

There is no option to change this within the laser parameters while coding or anywhere in PC-DMIS. This is currently solely controlled by hard code from the configuration. I have 3 different white light sensor lens and in order to change out one to another I have to open EGON every time.

+1
Færdig

White Light Scanning Sensor - Laser Scanning - Fixed or Non Fixed

Anthony Fotion 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 5

Please add a Forum section for Chromatic White Light Sensor Scanning or laser scanning to share discussions upon using a third probe setup on machines. This would be a huge imporvement.

I cannot find anny topics or discussions on this topic it is fairly new and would be a great addition.

+1

Adding created views in Legacy report.

Mitja Smrekar 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 0

I wish I could insert created views in legacy report. Now I can only recall views and make a screenshot of screen and this is not automated. Creation of complete legacy report take too much time but creating views is simple and faster. Legacy report is saved as PDF document.

+1

The ability to drop photos into reports at the click of a button

Daren King 10 år siden i Metrology Software / PC-DMIS opdateret af neil kay 7 år siden 2

a quicker more accessible option for reporting

+1
Færdig

Pattern Feature

Graham_Sam 10 år siden i Metrology Software / PC-DMIS opdateret af Neil Challinor 1 uge siden 2

We would like to be able to pattern around a specified feature as oppose to having to move the datum to that location, as pattern only operates around the datum.

0

Ability to change name of move points

mkrueger 1 uge siden i Metrology Software / PC-DMIS 0

Ability to name the move points, this way we can just copy paste if we use the same few without opening and viewing coords. 

0

home screen customization

Benjamin0731 3 uger siden i Metrology Software / PC-DMIS opdateret 3 uger siden 2

Allow home screen customization, especially the amount of recent are displayed. 

0

(Un)marking of move points

Filip C 3 uger siden i Metrology Software / PC-DMIS opdateret 2 uger siden 2

Currently, when I unmark feature for execution, the MOVE POINT gets unmarked as well (Even though there is an IF statement and a comment) = Mark

This led to big machine crash recently. Make it available for user to toggle, how PC-DMIS acts. E.g. when I want to unmark a feature=just the feature gets unmarked, nothing else.