+1

CAD model Export

Mitja Smrekar منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

I have a program with a CAD model in it, but I do not have a model in any other CAD format (stp, igs, prt...) only .cad from PC-DMIS. I need a function to export CAD model from PC-DMIS to other formats like stp and igs.


Situation is: I have only a PC-DMIS program and I need a model because we can not find that model anywhere.

+1

Separate Clearance Cubes = More efficient probe travel times.

Derek منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 3

When I import my 1-2-3 blocks for fixturing or whatever I bring in, I would like each of them to be able to have their own clearance cube instead of having to have a large cube encompassing the whole set up.  Sometimes with larger fixtures it would definitely speed things up if the probe didn't think it had to move so far away from my part just because the constraints of the CC are limited to the overall size of my imported fixturing.  And why stop there, also make it where if I don't have a fixture model I can manually set up a cube just for that single fixture piece as well.

+1

more information in the calibration results window

Aaron Baldauf منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Add more information to the calibration results window like: touch speed, scan speed, move speed, prehit/retract distance and so on. It would help to decide if the calibration has to be done again because of differences in these settings.


Here's an example:

Image 95


+1

Clearance cube around probe changer

Bill Kulpa منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Add something like a clearance cube around a probe changer if desired.

Basically like a saftey zone around the rack so that someone cant run probe, probe head, z rail into it while running a program.

+1

Lower matrix

Bill Kulpa منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Add a field in the lower level matrix calibration dialog box which informs the technician when the last time the lower matrix cal was performed.

+1

Bookmark location markers on scrollbar

gary wilson منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

When scrolling through a large program it can be difficult to find where you are in the program, even when clicking through bookmarks.

Colour coded markers on the scrollbar might help find bookmarks/breakpoints etc.

+1

Variable tolerance on scans/analysis view

gary wilson منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Some drawings show a gradual transition between profile tolerances but I'm currently unable to show this in a CMM report.

+1

Wind Chill CAD management option

Kingsld1 منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Add the ability to work with Wind Chill cad management.   At least around here, Team Center is dying. 

+1

Circle evaluation with constraint

Sonny Setyawidjaya منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 5 سنة 0

Found the constraint on radius/diameter of Circle, but need the constraint activated on the center of circle, to calculate actual radius/diameter on very small portion of circle.

+1

Option to remove Datum feature with MMC from report

Jonny منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل Rob Jensen منذ 4 سنة 1

When reporting features to Datums with MMC, the position of the features measured tend to always be zero, while the Datums the features are referenced to have a measurement? why is this? can the datums not be removed so only the features being measured show a measured value.