Ability to manage speed of simulation

Mike J. hace 2 años en Metrology Software / PC-DMIS actualizado por Neil Challinor hace 2 años 1

I would be so handy if the speed of simulation in off-line mode is manageble over a slide by mouse or by arrow up / down buttons. So I can high-speed trough for example a multi-hole pattern. 

0

CAD graphics improvement

Justin Doyle hace 2 años en Metrology Software / Inspect 0

Need to see flipped normals without having to click reverse cad faces first

0

Special License Required for TubeShaper?

pohneck hace 2 años en Metrology Software / TubeShaper 0
0

Move Point Feature jog mode offline

remy r hace 2 años en Metrology Software / PC-DMIS 0

Add a jog button to move the point in off line mode

to be easier to add clerance point, jump jigs, avoid collision, etc

thanks

Image 542

0

Be able to see the coordinates of the mouse pointer

Sara hace 2 años en Metrology Software / PC-DMIS actualizado por Kingsld1 hace 2 años 1

When I have used the scanner, I would like to see the coordinates of the pointer.

If I could, after defining the koordinatsystem, it would be very easy to check some dimensions just by hovering the pointer abow the cloud.

0

Put (*) sign to every probes' tips after Lower Matrix

Utku hace 2 años en Metrology Software / PC-DMIS 0

Hello,

After Lower Matrix is done, only "master" probe's tips are using (*) -uncalibrated- sign. Other probes' tips remain unchanged. This looks like "only master probes' tips must be calibrated and other probes' tips are ready to use". Yet this is false. I recommend to put (*) sign to every probes' tips after lower matrix is done. 

Best Regards. 

0

Give the ability to mute hits on auto-features.

RedgeXIII hace 2 años en Metrology Software / PC-DMIS 0

Often using an auto-plane with spiral movement, asymmetrical hole patterns cause hits to land in a hole. Adjusting auto-planes manually is not fun when any slight changes require that the hits be regenerated, and you have to start back from scratch. With the ability to mute hits, you can adjust the hits by hit count and spacer, then simply mute any hits that conflict with other features.