Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

Deeper automated feature naming convention

Alan_C منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 0

When programming offline I would like the naming conventions to more customizable. Example...If I select to measure a diameter that is .750 then I would like PC-DMIS to automatically assign that circle to be named CIR_750_1 and the next time (whenever that may be) a circle is selected with that same nominal diameter it would come up as CIR_750_2. Since I try to program with the least amount of movements in between features (path optimization) I don't always measure all of the Ø.750's at once. Just an example...Usually I would measure the Ø.750, then the Ø.129, then the second Ø.750. So I would like PC-DMIS to automatically assign (with the help of ID Setup)  the circles as CIR_750_1, CIR_129_1 and then CIR_750_2. Hope this makes sense...

0

cad model transparent

Selahattin Akkaya منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل ALBERT706 منذ 6 سنة 4

Hi guys

it would be nice to be able to make certain regions transparent.  For example: fixture model transparent, workpiece visible

have a nice day

0

Add a simple PASS or FAIL Inspection Summary At The End of the Report to indicate if a part is non-conforming

david carter منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 1

In a lot of instances an operator or Inspector wants a simple classification if a part is either good or Bad. Currently we can add the code to test for any out of tolerance features and display a report label programatically but this can be complex to a user. In most cases they wish to know of the part is any good or not, by having a PASS/FAIL label the inspector / operator does not have to review the report in all its detail. For Example

Image 287

Image 286

0

Graceful default handling of Find Hole Failure

Kingsld1 منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 0

Would like to see a graceful default way to handle Find Hole failures.  

For example the operator puts the probe in the approximate middle of the feature and lets PC DMIS try again and/or quick minimal manual feature measurement to temporarily reset the theoriticals. Probably would have to have a surface touch as part of the solution in case the surface isn't quite where it's expected.

0

Find Hole search area in the Auto Features Dialog

Kingsld1 منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 0

Add another parameter to appropriate Auto Features that sets the size of the Find Hole search area.  I know it can be done other ways but having your commonly used tools right at hand makes for a good work flow. 



0

NORMAL DISTANCE FROM PLANE

mbonilla منذ 7 سنة في Metrology Software / TubeShaper تم التحديث من قبل neil kay منذ 6 سنة 1

ALLOW DISTANCE MEASUREMENTS THAT ARE NORMAL TO A SELECTED PLANE.

0

Motorized probe magazine

Bill Kulpa منذ 7 سنة في Metrology Hardware / Coordinate Measuring Machines تم التحديث من قبل ALBERT706 منذ 6 سنة 4

Develop a motorized probe magazine much like every machining center has.

That way it could be mounted in the dead space at the end of the Y axis of most machines.

When a probe change is needed PC-DMIS would move the machine to a predetermined point for that port, the port would extend to the Z rail and unload or load a new probe. This would allow better use of the measuring envelop and enable use of that dead space at the end of the machine.


0

Allow measured feature coordinates to convert to auto features

Kyle Brummans منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 3

Often there are tools in auto features that are quite useful.  Often enough I spend time manually converting the coordinates of a measured feature into an autofeature to get the benefits it prescribes.

0

Add Angle for sample hit rotation (circle)

Kyle Brummans منذ 7 سنة في Metrology Software / PC-DMIS تم التحديث من قبل neil kay منذ 6 سنة 0

We can control the angles of the hits for the circle, it would be nice to independently control the angle of the sample hits

0
رفضت

The new Updater should list all versions of Pc-Dmis That you have installed on the computer

Michael A Wildschutz Sr منذ 7 سنة في Metrology Software / Universal Updater تم التحديث من قبل neil kay منذ 6 سنة 1

The all new Updater should be able to list all versions of Pc-Dmis that is installed on that particular computer not just the newest version

خدمة دعم العملاء من خلال UserEcho