Enhance vision probe support - lighting
Vision Probing is great (for the most part). However it would be nice to see a smoother transition when programming between two dissimilar machines or even CMM-V. Problems with settings translating between different style light configurations can pose some strange difficulites. Mostly settings getting lost or hidden.
Example: Right now I have a single tier ring light, my customer has a triple tiered ring light. I write programs where in sections I turned the ring light off - when the program is transported to their system - it is on. I am told this is because their setup is different.
If this were a probing Cmm I would simply select a different module/tip etc and move on - right in the probe toolbox.
☑ Override favorites to top of list - Sorting for Alignments /Dimensions
The ability to favorite a feature and sort those to the top of a list in alignments or when dimensioning.
(Perhaps a check box to ☑ Override favorites to top of list)
Many times I'm referencing a common datum feature and have to continuously hunt for it in the list.
Open Template / Program Template Search Path
Very Simple Idea. \
Add a set search path option for 'Template Programs'.
Add to the drop down menu under 'Open' ; 'Open Template'.
This then drives to your set search path for template programs.
Markers for flow control commands
I'd like to have the ability to press a button and have PC-DMIS place a book mark on every flow control operator I have in a program. When I'm editing it would be much easier to find them by jumping from book mark to book mark rather than having to look at every line of code. Often it's easy to miss one!
Maybe have an automated book mark option with different types of commands:
button for label
Button for flow controls
button for types of features with sub menu for different types of features
Call up a saved MSE group in Auto feature dialog
Add the ability to recall a Measurement Strategy Editor group directly in a Auto Feature Dialog box. Should result in less opening and closing of dialog boxes.
stylus calibration standard deviation
I'd like to have a graphic view of the roundness deviation of a stylus to determine what points on the stylus seem to be giving me the deviation.
sir i want to know the program check sum means, in the main program made any correction are not how to veryfy
18MMX1.5MM DISC NOT IN PROBE DESCRIPTION ... ???
how to added probes that they are not in the probe prescription.
Integrate filtering options into scan dialog
I'd like to have the filtering options available in scans (liner open, closed, freeform,etc) rather than having to construct a separate filtered feature set for each scan performed.
Comment Yes / No Auto-continue execution
Change the Comment Yes / No Auto-continue execution Default settings to be uncheck (Off).
Every Time I want to place a Yes / No Comment into the program I have too always uncheck the "Auto-continue execution". If I don't uncheck this check box I will get a Warning message "Enter an integer between 1 and 600" after selecting "OK".