+1
Need to have Circle U tolerance in the ISO-1101 standard
Randy Carr il y a 5 ans
dans Metrology Software / PC-DMIS
•
mis à jour par Rob Jensen il y a 4 ans •
2
Service d'assistance aux clients par UserEcho
ISO 1101 doesn't have a circle U modifier. We are adding ISO 1101 support for the UZ modifier for Profile tolerances in 2020 R2. Note: The UZ modifier in ISO is not the same as the circle U modifier in ASME, it has a different definition.
Completed - 2020 R2 Geometric Tolerance command supports ISO Profile with UZ and OZ modifiers.