+1

Need to have Circle U tolerance in the ISO-1101 standard

Randy Carr 5 år siden i Metrology Software / PC-DMIS opdateret af Rob Jensen 4 år siden 2

ISO 1101 doesn't have a circle U modifier. We are adding ISO 1101 support for the UZ modifier for Profile tolerances in 2020 R2. Note: The UZ modifier in ISO is not the same as the circle U modifier in ASME, it has a different definition.

Completed - 2020 R2 Geometric Tolerance command supports ISO Profile with UZ and OZ modifiers.

Kundesupport af UserEcho