Call up a saved MSE group in Auto feature dialog

Kingsld1 il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 1

Add the ability to recall a Measurement Strategy Editor group directly in a Auto Feature Dialog box.   Should result in less opening and closing of dialog boxes.

0

stylus calibration standard deviation

Bill Kulpa il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 0

I'd like to have a graphic view of the roundness deviation of a stylus to determine what points on the stylus seem to be giving me the deviation.

0

18MMX1.5MM DISC NOT IN PROBE DESCRIPTION ... ???

Oscar R il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 1

how to added probes that they are not in the probe prescription.

0

Integrate filtering options into scan dialog

Bill Kulpa il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 2

I'd like to have the filtering options available in scans (liner open, closed, freeform,etc) rather than having to construct a separate filtered feature set for each scan performed.

0
Terminé

Comment Yes / No Auto-continue execution

davehocum il y a 5 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 6

Change the Comment Yes / No Auto-continue execution Default settings to be uncheck (Off). 

Every Time I want to place a Yes / No Comment into the program I have too always uncheck the "Auto-continue execution". If I don't uncheck this check box I will get a Warning message "Enter an integer between 1 and 600" after selecting "OK". 

Image 233

0

varied audible feedback tones with tube shaper

Chip / Hydrasource il y a 5 ans dans Metrology Software / TubeShaper mis à jour par neil kay il y a 4 ans 1

When inspecting tubes there should be different tones for successful measurement instead of failed measurement.  There should also be different tones for first scan versus second scan on each straight.   Most important - there should be a different tone when measuring ends - unique from straight 1/2 pass fail.   Again indicating success or fail of attempted tube end scan.   YES there are different tones already so different tones are available - but those varied tones don't associate with desired function.  

0

Set Start Point location with Groups

davehocum il y a 6 ans dans Metrology Software / PC-DMIS mis à jour par neil kay il y a 4 ans 0

When a program execution is stop within a Group the Set Start Point will not be visible. With a large program that contains a large amount of Groups this can be difficult to find the Set Start Point location. Add a Set Start Point at the beginning of the Group and with the Group expanded move the Set Start Point at the last place of execution. This will eliminate the need to expand all Groups to locate the Set Start Point.

0

Custom Probe Builder Availability

davehocum il y a 6 ans dans Metrology Software / PC-DMIS mis à jour il y a 4 ans 1

The Custom Probe Builder should be available for all PC-DMIS CAD versions. This would be another addition to improve the UI.

0

NJB001 How to Get the slow key "Turtle" Out of of locked Mode.

michelle daggar il y a 6 ans dans Hardware / Coordinate Measuring Machines mis à jour par neil kay il y a 4 ans 0