Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

Ability to manage speed of simulation

Mike J. il y a 2 ans dans Metrology Software / PC-DMIS mis à jour par Neil Challinor il y a 2 ans 1

I would be so handy if the speed of simulation in off-line mode is manageble over a slide by mouse or by arrow up / down buttons. So I can high-speed trough for example a multi-hole pattern. 

0

CAD graphics improvement

Justin Doyle il y a 2 ans dans Metrology Software / Inspect 0

Need to see flipped normals without having to click reverse cad faces first

0

Special License Required for TubeShaper?

pohneck il y a 2 ans dans Metrology Software / TubeShaper 0
0

Move Point Feature jog mode offline

remy r il y a 2 ans dans Metrology Software / PC-DMIS 0

Add a jog button to move the point in off line mode

to be easier to add clerance point, jump jigs, avoid collision, etc

thanks

Image 542

0

Be able to see the coordinates of the mouse pointer

Sara il y a 2 ans dans Metrology Software / PC-DMIS mis à jour par Kingsld1 il y a 2 ans 1

When I have used the scanner, I would like to see the coordinates of the pointer.

If I could, after defining the koordinatsystem, it would be very easy to check some dimensions just by hovering the pointer abow the cloud.

0

Put (*) sign to every probes' tips after Lower Matrix

Utku il y a 2 ans dans Metrology Software / PC-DMIS 0

Hello,

After Lower Matrix is done, only "master" probe's tips are using (*) -uncalibrated- sign. Other probes' tips remain unchanged. This looks like "only master probes' tips must be calibrated and other probes' tips are ready to use". Yet this is false. I recommend to put (*) sign to every probes' tips after lower matrix is done. 

Best Regards. 

0

Give the ability to mute hits on auto-features.

RedgeXIII il y a 2 ans dans Metrology Software / PC-DMIS 0

Often using an auto-plane with spiral movement, asymmetrical hole patterns cause hits to land in a hole. Adjusting auto-planes manually is not fun when any slight changes require that the hits be regenerated, and you have to start back from scratch. With the ability to mute hits, you can adjust the hits by hit count and spacer, then simply mute any hits that conflict with other features.