0

3d rotation mode for clip plane

Kingsld1 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 1

Have a 3d rotation mode for clip planes.   It would make it much faster to cut away the stuff you don't want to see if you had a graphic you could drag around.   Maybe have handles you could translate in X, Y or Z and other handles so you could rotate the clip plane in I, J, and K.  

0

Shift nominals of selected features

Kyle Brummans 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

The ability to select several features and shift the nominal in any axis.

For Example Two Spheres on a Bar.  New revision change makes the bar 1mm longer.  Lets assume one of the spheres is 0,0,0.  I could select the feature(s) and move their coordinates in the desired direction.(Nominal, theo, target - perhaps a toggle for each). A lot of times this can be done by manipulating alignments, but not always and this is much simpler.

I could also see the ability to grow or shrink a group of features by 'x.xx' as useful as well.  A lot of parts have families with only minor changes and lots of similarities. 

0

Probe Utilities - Setup - Clearance Distance - In Z

davehocum 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

Probe Utilities - Setup - Clearance Distance -

In Z when qualification tool shank is perpendicular to Z axis: - This item defines the clearance distance in the Z axis when the qualification tool's shank is perpendicular to the Z axis. When the qualification tool is mounted on a horizontal shank, it sometimes needs extra Z clearance movement, especially on horizontal arm machines, to avoid collisions. The measurement units are the same as those used by your measurement routine.


This Clearance distance setting will move the probe after calibrating selected tips. Add the ability to use this setting to move the probe before and after calibrating selected tips.


0

Probe Utilities - Add Search, Sort and hide unmark tips for Active Tip List

davehocum 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

Probe Utilities

Add a Search box to search for a specific tip.

Add a Sort to have the ability to ascend or descend tips.

Add the ability to Hide unmark tips after selecting Mark Used.


0

Move Program Mode Icon to Measured Features Toolbar

Kingsld1 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

As far as I know Program Mode is only used with Measured Features.  Makes sense to me to take it off the graphic modes toolbar and move it to where it is used.   Easier to find and semi-logical.  

0

Optical flatness measurement

Wolle 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 10

We often have to measure very small optical flatnesses on contact surfaces. 

Here it would be useful if I had to Focus with once window only. 

Simply define the measurement window and the division of the measuring range analogous to the measuring method from Werth GmbH.


0

Add polar/catersian toggle to measured features

benjamin frickmann 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 2


Offer the same simple way to swap measured features between polar and cartesian coordinates, as is possible in auto features.

0

Min-Max Radius

Kyle Brummans 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

Canned  dimensional support for:

-Measuring a fixed radius then measuring an average point back to it's center point.

-Measuring a fixed radius then reporting out the high and the low points back to center and giving a max and min radius.

0

Scanning with the ability to lasso CAD points when picking Boundary points

Scott Wingard 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

The ability to lasso CAD points when picking your Boundary points when creating your scan

0

Probe prioritizing in loops

Salisbury83 6 år siden i Metrology Software / PC-DMIS opdateret af neil kay 5 år siden 0

When I create a part loop for 100 parts I would like the ability to run probe 1 on all 100 parts before switching to probe 2 and starting at part 1 again with the correct alignment.  If i create both probes in same loop program it takes more time changing probes than it does checking each part. The loop does create the alignments like this ABC[1] right now but once out of the loop and switching to probe 2 their is no way to recall alignment ABC[1] and start from part 1 thru 100 again. This would eliminate having to create external alignments using variables.

Kundesupport af UserEcho