
+1
Allow R (Radius) or Ø for features in FCF
Allow R (Radius) or Ø for features in FCF
Currently PC DMIS Software only allows Ø callout in FCF except in the Legacy FCF. I have drawing callouts where a Radius is used [ SEE ATTACHED PNG] This causes MMC to be incorrectly reported. Even the legacy does not allow Both R and Ø callouts to be reported differently in a single True Position FCF. You must choose one or the other and Primary Feature and Datum features will be reported as all R or all Ø. I would like to be able to report both R and Ø as needed in any True Position FCF.
Customer support service by UserEcho
Added functionality